5. System 3™ Conv. Initiating Devices/Bases (Cont.)
Model No.
Part No.
DT-140EP
500-688976
DT-190EP
500-688978
EAD-3
500-686214
MS-51
500-620503
MS-501
500-620522
MSM-K
500-698215
MSM-KD
500-698216
MSM-K-WP
500-698217
MSM-KD-WP
500-698218
MSM-EXP
500-698219
MSM-INST
500-698220
MSM-BOX
500-698221
PE-11
500-094150
PE-11T
500-095110
RR-11
500-694622
6. System Configurations
NOTE: When designing Fire Control Systems for various types of vessels, the designer should be
aware of the required vessel type, domestic and SOLAS regulations applicable for that vessel.
Typical Large System 3™ Control Panel
System Configurations
A. Compliance with Safety of Life at Sea (SOLAS) using USCG Approved Equipment.
B. POWER – Although the required two sources of power are available from the main and standby
generators, optional short term battery backup is also acceptable. The BC-35 Battery Charger
Module, the MM-35 Meter Module, and the BK-33 9 AH Battery Module serve this purpose.
C. ZONES – Fourteen smoke detection zones with manual stations included. The seven ZU-35TS modules
satisfy this requirement. One intrinsically safe zone requires ion detectors, supervised auto-
matic damper release, along with its own distinctive audible signal immediately outside the
area. The ZS-30 intrinsically safe zone module, the RM-30U release module, and the AE-30U
(no. 2) alarm extender module serve this purpose.
D. AUDIBLE ALARMS –
1. It is specified that bells are pulsed in order to distinguish fire signals from steady bells of the
emergency alarms. The MC-30 Master Code Module does this.
2. The SOLAS requirement of sounding bells in the crews spaces if the alarm signals at the
control panel have not received attention within 2 minutes is satisfied by the TL-30U Time
Limit Module and the AE-30U (no. 1) Alarm Extender Module.
E. SUPPLEMENTARY CONTROL –
Each of the fourteen zones has its separate AC unit which is to be shutdown upon alarm. The
three SR-32 modules serve this purpose. The SR-30 or SR-35 Relay Modules can also be used
for similar control functions.
Description
Rate Comp./Fixed Temp 140° Expl. Proof
Rate Comp./Fixed Temp 190° Expl. Proof
** Other Temp Require Special Order **
Weatherproof Air Duct Decector Enclsoure
Manual Stations N.O. SPST
Manual Stn. Double Action SPST
Metal Manual Station-Key
Metal Manual Station-Key-Double Action
Metal Manual Station-Key-Weather Proof
Metal Manual Sta-Key-Dbl Action-Weather Proof
Metal Manual Station-Explosion Proof
Metal Manual Station-Institutional
Surface Back Box
Photoelectric Detector
PE-11T Photo / Thermal Detector
Remote Relay Module
Catalog No.
6127
6127
---
6183
6183
6184
6184
6184
6184
6184
6184
6184
6173
6173
6173
35