Nz64 Blower Replacement - Napoleon High Country 6000 Series Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

If the glass should ever crack or break while the fi re is burning, do not open the door until the fi re is out. Do not
operate the appliance until the glass has been replaced. Contact your local authorized dealer/distributor for
replacement parts. DO NOT SUBSTITUTE MATERIALS.
This appliance is factory equipped with 5mm ceramic glass. Use only replacement parts as supplied by the
appliance manufacturer. DO NOT SUBSTITUTE MATERIALS.
10.7

NZ64 blower replacement

1. Remove the grill and fi lter by removing the two securing screws.
2. Remove the nut securing the blower bracket to the housing.
3. Lift the handles to pull the blower and bracket off the stud.
4. Slide the bracket and blower out of the housing.
5. Disconnect the wire connector from the blower.
6. Remove the old blower from the bracket by removing the four
screws.
7. Secure the new blower to the existing bracket using the four
screws.
8. Slide the new blower/bracket assembly into the housing. Ensure
that the blower bracket slides into the clips at the back of the
housing on either side.
9. Push the assembly into the housing as far in as possible.
10. Secure the assembly to the housing using the nut removed in step
B.
11. Re-secure the grill by replacing the 2 securing screws.
maintenance
NUT
BLOWER
BRACKET
STUD
HANDLES
HOUSING
CLIP
BLOWER/BRACKET ASSEMBLY
W415-1501 / E / 12.17.18