B. General Operating Parts
Figure 3.2 references the general operating parts of the
appliance and the section of this manual in which they are
discussed.
DECORATIVE FRONTS
(NOT SHOWN)
SECTION 4.B.
LED
REPLACEMENT
SECTION 4.C.
OPERATION DURING
A POWER OUTAGE
SECTION 3.J.
FIXED GLASS ASSEMBLY
(NOT SHOWN)
SECTION 4.B & 4.C.
RATING PLATE/GLASS CLIP TOOL LOCATION
Figure 3.2 General Operating Parts
Rating Plate/Glass Clip Tool Location
The rating plate for this model is located underneath the
firebox affixed to a tray that must be accessed using a
1/4 inch nut driver. See Figure 3.3. To access the rating
plate, remove the screw that secures the tray to the appli-
ance bottom and pull the tray out.
The glass clip removal/installation tool is also located in
this area. To access the glass clip tool, remove the screw
that secures it to the appliance bottom.
RATING PLATE
Figure 3.3 Rating Plate/Glass Clip Tool Location
8
CLEAR SPACE
SECTION 3.A.
SECTION 3.B.
GLASS CLIP TOOL
Majestic • MARQ36IN-B, MARQ42IN-B Owner's Manual • 2614-981 Rev. C • 4/19
C. Fuel Specifications
WARNING! Risk of Fire or Explosion! Appliance must
be set up for compatible gas type!
• This appliance is designed to operate on either natural
gas or propane. Make sure the appliance is compatible
with gas type selected for installation site.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specified
and approved parts.
D. Wall and Mantel Temperatures
ANSI/CSA Standards
The American National Standards Institute (ANSI) and
MANTEL
Canadian Standards Association (CSA) write the safety
and performance standards to which all gas fireplaces
are tested. The following are the allowable temperatures
around and on a gas fireplace per the ANSI/CSA
standards:
Combustible Mantel and Surfaces around a Fireplace
The allowable temperature rise above ambient is
117°F for all exposed combustible surfaces around the
fireplace, including the mantel, when installed according
to the installation instructions. Non-combustible surfaces
and mantels do not have a maximum temperature limit;
however the installation instructions must still be followed
for any restrictions on placement of non-combustible
materials on or around the fireplace.
Example: The mantel above a fireplace in a room
that is 70°F is allowed to reach but not exceed
187°F (70°F+117°F = 187°F).