a 1 exhaust connection
for exhaust ducting  250 mm.
The exhaust connection is not used
for recirculation mode.
b 1 mounting rail
for mounting the DAR 12xx on a
wall.
c 2 mounting brackets
for mounting the DAR 12xx on a
wall.
d 2 cover caps
3 screws, 5 x 60 mm and
3 plugs, 8 x 50 mm
for fixing to the wall (DAR 12xx only).
The screws and plugs are designed
for use in solid walls only.
For other types of wall construction,
alternative fixings will be required.
Make sure the wall is able to take the
weight of the rangehood.
2 self-locking screws, M6 x 16 mm
for attaching the DAR 12xx to the
mounting rail.
4 screws, M4 x 11 mm with base and
2 clamps
for securing the DRDC and DRUU
fascia panels (DAR 12xx only).
8 screws M4 x 8 mm
for fastening the cover caps and the
clamps (DAR 12xx only).
4 screws, 5 x 35 mm
for securing the DAR 11xx rangehood.
Keep the following in a safe place: