Calibration Procedures; Calibration Menu Definitions - CAMBRIDGE DL-CSW-10AT-LFT Installation, Setup And Operation

Carriage-mount lift truck scale system
Table of Contents

Advertisement

2.0 CALIBRATION PROCEDURES

C1 Zero All
C2 Zero
C3 Span Point
C4 to C7 Span points
END

2.1 Calibration Menu Definitions:

Raw counts, (pitch and roll if in angle mode) will be displayed.
When
ZERO
calibration span points will be cleared.
If in angle mode the pitch and roll offsets will also be zeroed.
Zeroed raw counts, (pitch and roll if in angle mode) will be
displayed. When
and all calibration span points will NOT be cleared.
If in angle mode the pitch and roll offsets will also be zeroed.
The last calibration weight will be displayed then the
actual weight on the scale will be displayed.
If you do not wish to change the span point, press the
TARE key to exit without making any changes.
If the displayed weight does not match the known test
weight, press the
Use the steps described in section 1.4 for numeric entry.
When the weight is correct press the
the new value.
C4 to C7 are for linearity correction. They can be used in
order and in any quantity or not at all if no correction is
necessary.
You may also return to C4 to C7 later and add a new
correction point without effecting any original calibration
points.
The last calibration weight will be displayed then the actual
weight on the scale will be displayed. If no calibration
weight has been entered at this span point "notset" will be
displayed then the actual weight on the scale is displayed.
If the displayed weight does not match the known test
weight, follow the steps described for C3 Span point on
adjusting the weight and entering the value.
Exits back to the main Menu.
is pressed an analog aero is done and all
ZERO
is pressed an analog zero is done
ZERO
key to enter the correct weight.
PRINT
key to enter
17

Advertisement

Table of Contents
loading