Fan coil – product overview
Product
Communicating
RDG100...
Versatile thermostats with
control output signal (ON/OFF)
or mod. (PWM or 3-pos.)
RDG110
Robust thermostat with
relay outputs (SPDT) for
ON/OFF – control sequences
RDG140
Thermostat for mod. control
sequences with (DC 0...10 V)
output signals
RDG160..
Thermostat for mod. control
sequences with (DC 0...10 V)
output signals for valve and
fan control (ECM) DC 0...10 V
RDG160KN
Communicating thermostat for
mod. control sequences with
DC 0...10 V or ON/OFF output
signals for valve and fan control
DC 0...10 V (ECM), 1- or 3-speed
10
Application
– 2-pipe (ON/OFF, PWM or 3-pos.)
– 2-pipe with electric heater
– FCU: (ON/OFF, PWM or 3-pos.)
– el. heater: (ON/OFF, PWM or 3-pos.)
– 2-pipe and radiator
– FCU: (ON/OFF, PWM or 3-pos.)
– radiator: (ON/OFF, PWM or 3-pos.)
– 4-pipe (ON/OFF, PWM and/or 3-pos.)
– 4-pipe with electric heater
– FCU: (ON/OFF, PWM and ON/OFF, PWM or 3-pos.)
– el. heater: (ON/OFF)
– 2-stage heating or cooling
– FCU: (ON/OFF, PWM or 3-pos.)
– 2-pipe (ON/OFF)
– 2-pipe (ON/OFF) with el. heater (ON/OFF)
– 2-pipe (ON/OFF) and radiator (ON/OFF)
– 4-pipe (ON/OFF)
– 2-stage (ON/OFF) heating or cooling
– 2-pipe (DC 0...10 V)
– 2-pipe (DC 0...10 V) with el. heater (DC 0...10 V)
– 2-pipe (DC 0...10 V) and radiator (DC 0...10 V)
– 4-pipe heating (DC 0...10 V) and cooling (DC 0...10 V)
– 2-stage (DC 0...10 V) heating or cooling
– 2-pipe (DC 0...10 V)
– 2-pipe (DC 0...10 V) with el. heater (DC 0...10 V)
– 2-pipe (DC 0...10 V) and radiator (DC 0...10 V)
– 4-pipe heating (DC 0...10 V) and cooling (DC 0...10 V)
– 2-stage (DC 0...10 V) heating or cooling
With ECM fan control (DC 0...10 V signal)
– 2-pipe (ON/OFF)
– 2-pipe (DC 0...10 V)
– 2-pipe (ON/OFF) with el. heater (ON/OFF)
– 2-pipe (DC 0...10 V) with el. heater (ON/OFF)
– 2-pipe (DC 0...10 V) with el. heater (DC 0...10 V)
– 2-pipe (ON/OFF) and radiator (ON/OFF)
– 2-pipe (DC 0...10 V) and radiator (ON/OFF)
– 2-pipe (DC 0...10 V) and radiator (DC 0...10 V)
– 4-pipe heating (ON/OFF) and cooling (ON/OFF)
– 4-pipe heating (DC 0...10 V) and cooling (DC 0...10 V)
– 2-stage (ON/OFF) heating or cooling
– 2-stage (DC 0...10 V) heating or cooling
With 3- or 1-speed fan
– 2-pipe (DC 0...10 V)
– 2-pipe (DC 0...10 V) with el. heater (DC 0...10 V)
– 2-pipe (DC 0...10 V) and radiator (DC 0...10 V)
– 4-pipe heating (DC 0...10 V) and cooling (DC 0...10 V)
– 2-stage (DC 0...10 V) heating or cooling
Stand-alone
with
Stand-alone
7-day
program
RDG100
RDG100T
RDG100T/H
RDG110
RDG140
RDG160
Communicating
RDG100KN
(KNX)
RDG160KN
(KNX)
RDG160KN
(KNX)

Hide quick links:

Advertisement

Table of Contents
loading