Security Levels

Security Level
0
1
2
3

Locking Fixture

To lock the fixture:
Step 1. At a Status Screen, press [MENU] and scroll to "Lock Fixture".
Step 2. Press [OK].
Step 3. Use [LEFT ARROW] or [RIGHT ARROW] keys to highlight "YES" ", press [OK].
Step 4. Fixture is now locked.
Note: When the Fixture is Locked only the [ESC]/[MENU] key is functional. Pressing this key will display a request
for a password. When a valid password is entered the fixture is unlocked to the security level of the entered password.

4. Presets

Presets are Color Mixes that are stored in the Fixture, they can be recalled to reproduce a specific output from the
fixture. Presets are made up of a Color Mix; Red, Green, Blue, and White. They also have Intensity associated with
them.
Presets can be recalled via the User interface or by a DMX channel, when under DMX control. The Preset's Intensity
is applied if the User Interface is used; if DMX, the DMX Intensity channel is used for Intensity.

Presets Types

Presets are classified as Locked, Protected, or User. The type of preset determines what aspects of the Preset can be
modified.
Locked
Locked Presets are factory Calibrated, and their Color Mix cannot be changed by the user. Their Intensity can be
changed. Three Presets (2-4), "Warm White', "Cool White", and "Day Light", are Locked.
Preset 0, the "off" preset is also Locked to the OFF value.
Protected
Protected Presets are also Factory Calibrated, and by default are Protected from changes to their Color Mix. Their
Intensity can be changed. Protected Presets are Presets 5-25. They can be Un-Protected by setting "Protected" to
"No"; see section on Settings. If Un-Protected these presets function like User Presets.
The Factory Calibrated values for the protected presets can be re-loaded to the original factory calibration settings by
setting "Load Factory" to "Yes" "; see section on Settings.
User
User Presets can have their Color Mix and Intensity changed without restriction.
2 2
OPERATION AND PROGRAMMING
Description
System is locked; the only key that is active is the Menu/ESC Key. When this key is pressed a
PassPIN is requested.
All keys are Active.
You can select any Preset, and change Intensity, set DMX Address.
Editing and Saving of Presets is added to Level 1 functionality.
Operationally the same as level 2, however all settings are available on the Settings screen.