TDS5000B Series
Digital Phosphor Oscilloscopes
071-1421-01
Warning
The servicing instructions are for use by qualified
personnel only. To avoid personal injury, do not
perform any servicing unless you are qualified to
do so. Refer to all safety summaries prior to
performing service.
www.tektronix.com
*P071142101*
071142101

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDS5000B Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Tektronix TDS5000B Series

  • Page 1 Instructions Option 1R Rackmount Kit TDS5000B Series Digital Phosphor Oscilloscopes 071-1421-01 Warning The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
  • Page 2: Contacting Tektronix

    Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material.
  • Page 3: Service Safety Summary

    Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power and disconnect test leads before removing protective panels, soldering, or replacing components. To avoid electric shock, do not touch exposed connections. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 4 Service Safety Summary TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 5: Kit Description

    PHILLIPS 5 ea WASHER: FLAT, NYLON 2 ea 351-1095-00 SLIDE, DRAWER, EXTENDERS: SLIDERS 2 ea RACK: MOUNTING SCREWS, NUT BLOCKS 1 ea 200-4866-00 COSMETIC COVER, RACKMOUNT 1 ea 386-7340-00 PLATE: SHEET METAL, GUARD BRACKET TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 6 Kit Description Figure 1 on page 4 Quantity Part number Description 1 ea 386-7300-00 PLATE: STEEL, BRACKET SPACER 2 ea 367-0525-00 HANDLE: BRACKET, AL, GRAY NS - Not Saleable Figure 1: Rackmount kit parts TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 7: Warranted Characteristics

    Cooling air enters on the bottom and right sides as shown in Figure 2. You must provide adequate cool air to meet the ambient temperature requirements listed in Table 1. Hot air out (rear) Measure input air temperature Cool air in Figure 2: Instrument cooling TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 8: Clearance Requirements

    CAUTION. Adhering to these clearance requirements provides the rack-mounted instrument with sufficient clearance for air circulation and accommodation of the power cord and mounting hardware. Failure to provide these clearances can result in overheating and can cause instrument faults or failure. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 9 482.600 mm (19.000 in) 30.480 mm (1.200 in) 265.938 mm 258.639 mm 161.925 mm (10.470 in) (10.160 in) (6.375 in) 465.480 mm 29.72 mm (18.326 in) (1.170 in) Figure 3: Instrument with rack adapter installed TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 10 Kit Description TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 11: Installation Instructions

    If you need further details for disassembling or reassem- bling the product, refer to the appropriate product manual. Contact your nearest Tektronix Service Center or Tektronix Factory Service for installation assistance. WARNING. To prevent the rackmounted instrument from tipping forward onto the operator, install the instrument so that the operator will be able to access all of its rear-panel connectors without pushing down on the instrument.
  • Page 12 13. Remove the two T-15 Torx screws that secure the bottom cosmetic cover to the instrument. Remove the bottom cosmetic cover from the instrument. 14. Remove the plastic VGA panel from the instrument. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 13 (2) Line cord Accessory VGA panel pouch bracket T-15 Torx Right-side screw (2) cover CD-drive trim T-15 Torx screw (2) Bottom cosmetic cover T-15 Torx screw (2) Figure 4: Strip instrument for conversion TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 14 This section describes mounting the rackmount parts to the instrument. 1. Remove the front section of each of the two tracks. See Figure 5. Remove this section from each track. Figure 5: Prepare tracks for mounting TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 15 Check that the track button latches are oriented correctly: the right-side latch is located toward the bottom of the rackmount panel and the left-side latch is located toward the top of the rackmount panel. Refer to Figure 7 on page 14. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 16 6. Use a T-15 Torx screw to fill the screw hole under the plastic VGA panel. 7. If desired, install the cosmetic top cover using three Torx screws from the instrument. See Figure 8 on page 15. 8. Reinstall the two top feet/line cord holders. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 17 Truss-head 10-32-.5 screws (4) Figure 8: Installation of rackmount assemblies This completes the installation of the rack-adapter hardware to the instrument. To complete the installation, do the following procedure: Rackmount the Rack- Adapted Instrument. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 18: Rackmount The Rack-Adapted Instrument

    Verify that the rack does not become unstable with the instrument fully extended. Do not leave the instrument extended when finished accessing the rear panel. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 19 Select the mounting position in rack: Select two 0.5 inch-spaced holes in the front rail. Verify that the 4.36 inch and 10.500 inch clearances exist relative to those mounting holes. See Figure 10 on page 19. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 20 673.1 mm (26.50 in) maximum Rear bracket Right slide-out track assembly Outer track Round cut out Front flange (mounts to front rail of rack) Inner track Left slide-out track assembly Figure 9: Assembly of slide-out track assemblies TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 21 162 mm (6.375 in) 266.700 mm 29.8 mm (10.500 in) (1.14 in) 21.081 mm (.830 in) 12.7 mm (0.50 in)(for correct position of securing holes) Figure 10: Vertical clearances for rack installation (left-front rail shown) TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 22 Use two flat-head screws if the cabinet rails have countersunk mounting holes; otherwise use two pan-head screws Mounting Method A Mounting Method B Figure 11: Installation of slide-out track assemblies in rack (top view) TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 23: Install The Instrument

    H Retighten the four screws and push the instrument all the way into the rack. If the tracks do not slide smoothly, readjust the level using the method just detailed. H When leveling is completed, tighten the 10-32 screws using 28 inch-lbs of torque. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 24: Finishing The Installation

    Repeat for the second mounting hole. Tighten both screws using 25 inch-lbs of torque. H Install one of the two remaining screw/washer assemblies in the lower hole of the right-front bracket using the method just described. H Reinstall the power cord. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 25: Using The Cd Guard

    Depending on the location of the adjacent instruments in the rack, you may have to access the CD tray from the back of the rack. TDS5000B Series (Option 1R) Rackmount Kit...
  • Page 26 4. When you are done using the CD drive, move the guard down and verify that the red indicator is not showing. See Figure 12. 5. Push the instrument all the way back into the rack. g End of document g TDS5000B Series (Option 1R) Rackmount Kit...