Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage. The load
is not electrically isolated from the mains even when the device is switched off.
Risk of destruction if the set operating mode and load type do not match. Set correct operating
mode when connecting or exchanging the load.
Fire hazard. For operation with inductive transformers, each transformer must be fused on the
primary side in accordance with the manufacturer's instructions. Only safety transformers ac-
cording to EN 61558-2-6 may be used.
These instructions are an integral part of the product, and must remain with the end customer.
2
Intended use
Operation with suitable cover
Mounting in appliance box according to DIN 49073
Operation with neutral conductor
Switching of incandescent lamps, HV halogen lamps, electronic or inductive transformers
with halogen or LED lamps, switchable or dimmable HV-LED or compact fluorescent
lamps, electrothermal actuators in combination with room temperature controller covers
Operation without neutral conductor
Switching of incandescent lamps, HV halogen lamps, electronic or inductive transformers
with halogen or LED lamps, dimmable HV-LED or compact fluorescent lamps
Product characteristics
Switch-on via bulb-preserving soft start
Connection of extensions possible
Electronic short-circuit protection with permanent switch-off after 7 seconds at the latest
Electronic over-temperature protection
Flickering of the connected lamps through centralised pulses from the power stations.
This does not represent any defect in the device.
Operation with neutral conductor
Device is powered via phase conductor and neutral conductor , therefore there is no lead-
ing edge phase control or trailing edge phase control.
Operation without neutral conductor
Device is powered via the phase conductor and the connected load and therefore works
in the leading edge phase control or trailing edge phase control principle
Automatic or manual setting of the suitable operating mode for the load
Display of the set operating mode by means LED
Brief flickering upon load detection possible. No operation is possible during load detec-
tion.
82400512
24.05.2019
1 / 7

Advertisement

loading

Summary of Contents for Gira 5405 00

  • Page 1 System 3000 Electronic switching insert Electronic switching insert Order no.: 5405 00 Operating instructions Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please read and follow manual fully.
  • Page 2: Operation

    System 3000 Electronic switching insert Operation These instructions describe operation with a button cover. Operation with different covers is de- scribed in the instructions for the cover in question. Operation using 2-wire extension with but- ton cover or push-button corresponds to operation on the main device. Switch load ■...
  • Page 3 System 3000 Electronic switching insert Push-button, NO contact Connect 600 W LED lamps or compact fluorescent lamps at most per 16 A circuit breaker. When connecting transformers, observe the data of the transformer manufac- turer. The connected load on LED lamps is dependent on the type of lamp and installation con- ditions.
  • Page 4: Technical Data

    System 3000 Electronic switching insert – Incandescent lamps, HV halogen lamps, electronic transformers for halogen or LED lamps that can be dimmed according to the trailing edge phase control principle, HV-LED or compact fluorescent lamps that can be dimmed according to the trailing edge phase control principle.
  • Page 5: Troubleshooting

    System 3000 Electronic switching insert Mixed load ohmic-capacitive 20 ... 400 W capacitive-inductive not permitted ohmic-inductive 20 ... 400 VA Ohmic and HV LED typ. 3 ... 100 W Ohmic and compact fl lamp. typ. 3 ... 100 W Power specifications including transformer dissipation. Operate inductive transformers with at least 85% nominal load.
  • Page 6: Warranty

    The warranty is provided in accordance with statutory requirements via the specialist trade. Please submit or send faulty devices postage paid together with an error description to your re- sponsible salesperson (specialist trade/installation company/electrical specialist trade). They will forward the devices to the Gira Service Center. 82400512 24.05.2019...
  • Page 7 System 3000 Electronic switching insert Gira Giersiepen GmbH & Co. KG Elektro-Installations- Systeme Industriegebiet Mermbach Dahlienstraße 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel +49(0)21 95 - 602-0 Fax +49(0)21 95 - 602-191 www.gira.de info@gira.de 82400512 24.05.2019 7 / 7...