Siemens SIMATIC S7-300 Series Reference Manual page 149

Cpu specifications
Hide thumbs Also See for SIMATIC S7-300 Series:
Table of Contents

Advertisement

MPI Addressing
You Have a CPU as of Order Number and
Version:
6ES7316-1AG00-0AB0, version 01
and STEP 7 V4.02 or later
The CPU accepts the MPI addresses configured by
you in STEP 7 for the relevant CP/FM in an S7300
or
automatically determines the MPI address of the
CP/FM in an S7-300 on the pattern
MPI addr. CPU; MPI addr.+1 MPI addr.+2 etc.
CPU
CP
MPI
MPI
addr.
addr.
"x"
MPI with 19.2 Kbps
With STEP 7 as of V4.02 you can set a transmission rate for the MPI of 19.2 Kbps.
The CPUs support 19.2 Kbps as of the following order numbers:
6ES7312-5AC01-0AB0, version 01
6ES7313-1AD02-0AB0, version 01
6ES7314-1AE03-0AB0, version 01
6ES7314-5AE02-0AB0, version 01
6ES7315-1AF02-0AB0, version 01
6ES7315-2AF02-0AB0, version 01
PLC S7-300, CPU Specifications CPU 312 IFM to CPU 318-2 DP
A5E00111190-01
CPU Function, depending on CPU and STEP 7 Version
Your CPU version and order number is lower
6ES7312-5AC01-0AB0, version 01
6ES7313-1AD02-0AB0, version 01
6ES7314-1AE03-0AB0, version 01
6ES7314-5AE02-0AB0, version 01
6ES7315-1AF02-0AB0, version 01
6ES7315-2AF02-0AB0, version 01
The CPU automatically establishes the MPI
address of the CP/FM in an S7–300 on the
pattern MPI addr. CPU; MPI addr.+1 MPI addr.+2
etc.
CP
CPU
MPI
MPI
addr.
addr.
"z"
than the following:
and STEP 7 < V4.02
CP
CP
MPI
MPI
addr.+1
addr.+2
4-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents