Advertisement

T2 ES/ T4 ES
TURBINES
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the T2 ES and is the answer not in the manual?

Questions and answers

Summary of Contents for CorroVenta T2 ES

  • Page 1 T2 ES/ T4 ES TURBINES USER MANUAL...
  • Page 3: Table Of Contents

    Alarms ............................... 17 Service Reminder ............................17 Maintenance and service ......................... 18 Fault finding ..............................19 Technical data .............................. 20 Interface Map for CTR A2ES, CTR A4 ES and CTR A ES ................21 © Corroventa Ltd. 2017.02 1 (25)
  • Page 4: Intended Use

    User Manual CTR T ES Intended use The CTR T ES, including the CTR T2 ES and the larger CTR T4 ES, is the first digital turbine family developed and intended for construction drying and water damage restoration where the machines are used for suction and pressure drying in combination with adsorption dryers.
  • Page 5: Manufacturing Directive

    Manufacturing Directive CTR T2 ES and the CTR T4 ES are CE approved. Waiver of Liability • Faulty, incorrect installations and/or incorrect use can cause damage to property and human injury. • The manufacturer assumes no responsibility or liability for damages or injuries caused by non-compliance with the instructions herein, use for other purposes than the intended, or failure to observe its warnings.
  • Page 6: Safety Information

    22. The turbine must never be used with any other accessories than those listed in this manual or those specifically approved by Corroventa Avfuktning AB. 23. When used with Corroventa water separator, the turbine must always be powered through the power outlet of the water separator.
  • Page 7: Relative Humidity And Its Effect On Substances

    Functions in yellow and blue area. Functions within dashed area. Condensation dryers are, in accordance with the diagram above, used in hot and humid conditions provided the goal and aim is drying of rooms, ambient air. © Corroventa Ltd. 2017.02 5 (25)
  • Page 8: Delivery Inspection

    Manual 1 pc Product Overview Below pictures present CTR T ES with all its external features and controls. The CTR T2 ES is shorter than the CTR T4 ES but all the external features are the same. Control Panel Foldable carrying...
  • Page 9: Drying Methods

    The initial removal of free water also saves time. Pressure drying might free particles/fibers from the construction and thus release them in the air. If this is a potential problem, another method should be applied. © Corroventa Ltd. 2017.02 7 (25)
  • Page 10: Installation

    4. Put the power switch in position On. When the display has started up, for new job with default settings, push Start. To operate with the same settings as last time the machine was used, push Resume. 5. Adjust the speed until desired air flow is obtained. © Corroventa Ltd. 2017.02 8 (25)
  • Page 11: Accessories And Consumables

    Top left and right buttons – Menu navigation only. Never changes any settings. Home button Return to the default view Info button Presents information. On-board manual © Corroventa Ltd. 2017.02 9 (25)
  • Page 12 © Corroventa Ltd. 2017.02 10 (25)
  • Page 13 The third option, Relation, is only available when the machine is networked and slaved to another turbine. © Corroventa Ltd. 2017.02 11 (25)
  • Page 14 To activate Timer, enter the Timer menu and push Activate. Confirm or, if required, edit the system time and date which is presented in the following format: YY:MM:DD / HH:MM. Push OK. © Corroventa Ltd. 2017.02 12 (25)
  • Page 15 Menu System: The menu system is by default set to Advanced with all functions visible and accessible. If set to Basic, the more advanced functions, flow are removed from the menu system. Key Pad lock: Possibility to deactivate the key pad lock. © Corroventa Ltd. 2017.02 13 (25)
  • Page 16 Operation hours for the last 14 days • Consumed energy, kWhrs, for the last 14 days. The last value, the bar at the far right in the respective graphs, is the current hour or current day as applicable. © Corroventa Ltd. 2017.02 14 (25)
  • Page 17: Network Functions

    Master. If the user selects to do necessary changes to the settings through the Master, the display of the selected Slave flashes while the changes are made so as to allow for easy identification and avoid confusion. © Corroventa Ltd. 2017.02 15 (25)
  • Page 18: How To Network Machines

    Master or do the necessary changes to the settings on the machine itself. When being edited through the Master, the slave machine will start to blink its display backlight so that the user can see what machine is selected. © Corroventa Ltd. 2017.02 16 (25)
  • Page 19: Alarms

    The machine is set to provide a service reminder every twelve months. The reminder is presented as an alarm but it does not affect the operation of the machine. The service reminder function is reset under Setup and Maintenance. © Corroventa Ltd. 2017.02 17 (25)
  • Page 20: Maintenance And Service

    4. Turn the knob anti-clockwise to remove the filter holder. 5. Remove and discard the old filters, install the new ones. 6. Put the filter holder back in position. Turn knob anti- clockwise to remove filter holder. © Corroventa Ltd. 2017.02 18 (25)
  • Page 21: Fault Finding

    15 minutes. Reconnect the power and start the turbine. Turbine failure. If the above does not rectify the operation, please contact your retailer for repair. © Corroventa Ltd. 2017.02 19 (25)
  • Page 22: Technical Data

    Technical data CTR T2 ES Typ LAF 50 LAF 50E LAF 50E2 LAF 100 LAF 100E LAF 150 LAF 150E Up to 180 Air volume (m (continuously variable) Up to 260 Pressure (mbar) (continuously variable) Noise, dBA (3m) approx. 48 *...
  • Page 23: Interface Map For Ctr A2Es, Ctr A4 Es And Ctr A Es

    Interface Map for CTR A2ES, CTR A4 ES and CTR A ES Top Menu...
  • Page 24 Sublevels Reset Info Info Reset Info Info Info...
  • Page 25 Functional test of the display. This is to test that Change all pixels are active Change Run… Change Reset… Change Pressure… Change View…...
  • Page 26 Create Activate Activate Deactivate Edit...
  • Page 27 Info Change...
  • Page 28 DO YOU HAVE ANY QUESTIONS OR DO YOU NEED OUR SUPPORT? Please visit www.corroventa.com or call us at +44 (0)161-244 95 23 and speak to an expert. We have the knowledge and the equipment to find a solution as efficiently as possible.

This manual is also suitable for:

T4 esTurbine t2T2

Table of Contents