® Contents R&S SZU100A Contents 1 Safety Information..............5 2 Documentation Overview............6 3 About This Manual..............7 4 Welcome to the R&S SZU............. 8 5 Preparing for Use..............10 5.1 Unpacking and Checking the R&S SZU..........10 5.2 Putting into Operation................ 11 5.3 Adjusting the Feet................12 6 Instrument Tour..............
® Contents R&S SZU100A 8 Remote Control of the R&S SZU........36 Glossary: List of Frequently Used Terms and Abbrevia- tions..................38 Index..................40 Manual 1425.3061.02 ─ 04...
® Safety Information R&S SZU100A Safety Information The product documentation helps you use the R&S SZU safely and efficiently. Follow the instructions provided here and in the printed "Basic Safety Instruc- tions". Keep the product documentation nearby and offer it to other users.
Documentation Overview This section provides an overview of the R&S SZU user documentation. You find it on the product page of the R&S SZU, see www.rohde-schwarz.com/manual/ szu100a. The User Manual of the R&S SMW is provided at www.rohde- schwarz.com/product/SMW200A/User Manual.
® About This Manual R&S SZU100A About This Manual This user manual which you have received as printed book with your instrument, provides all the specific information about the R&S SZU. The instrument functions and settings concerning the R&S SMW are described in the main R&S SMW user manual.
® Welcome to the R&S SZU R&S SZU100A Welcome to the R&S SZU The Rohde & Schwarz R&S SZU is an IQ upconverter designed for the 60 GHz frequency band. These frequencies are used in modern high-performance wire- less communication standards, e.g. IEEE802.11 ad. Operating in the 60 GHz fre- quency band enables devices to communicate at multi-gigabit speed, with data transfer rates of several Gbit/s.
Page 9
® Welcome to the R&S SZU R&S SZU100A adjusts the frequency and level values to the output values of this downstream instrument. Thus the R&S SMW controls the R&S SZU almost entirely. You only need to select single ended or differential mode for the baseband connection. It is recom- mended that you work in differential mode due to better common mode noise suppression over the single ended connection.
® Preparing for Use R&S SZU100A Unpacking and Checking the R&S SZU Preparing for Use This section explains how to take an R&S SZU IQ Upconverter into operation. It includes the controls and connectors of the R&S SZU, and provides all the infor- mation necessary for connection.
® Preparing for Use R&S SZU100A Putting into Operation Putting into Operation The IQ upconverter is designed for use under laboratory conditions. General ambient conditions: ● The ambient temperature and humidity must be in the ranges specified for operation and for compliance with specifications (see the data sheet).
® Preparing for Use R&S SZU100A Adjusting the Feet Adjusting the Feet The R&S SZU has four adjustable feet you can mount at each side of the unit. Manual 1425.3061.02 ─ 04...
® Instrument Tour R&S SZU100A Front View Instrument Tour Front View Test port adapter (waveguide port) At the front, the R&S SZU covers the interface to the DUT, that is the output of the RF signal. Table 6-1: R&S SZU IQ Upconverter front views R&S SZU with standard WR15...
® Instrument Tour R&S SZU100A Rear View Figure 6-1: Assignment of the test port adapter 1 = Hole for pin of the DUT 2 = Hole for additional pin 3 = Alignment pin Refer to the data sheet for more details on the type of waveguide port.
® Instrument Tour R&S SZU100A Rear View Figure 6-3: Rear view of the R&S SZU 1 = Power supply connector 2 = IQ input connectors 3 = Status LED 4 = USB interface 5 = LO signal input and output 6 = Trigger connector 6.2.1...
® Instrument Tour R&S SZU100A Rear View Shock hazard The input voltage and current must not exceed the maximum values according to the labeling or the data sheet. It is recommended that you use the included power supply unit for the operation of the R&S SZU.
® Instrument Tour R&S SZU100A Rear View R&S SZU status Description Internal error E.g. over temperature, power failure, fan failure. External error E.g. LO level out of range. blinking (6Hz) 6.2.4 USB Interface Universal serial bus (USB) interface of type B (Figure 6-3, (4)).
® Startup R&S SZU100A Startup This section explains the required steps and components for starting up with R&S SZU. It describes how to connect the IQ upconverter with the R&S SMW, what you have to observe and how to configure the system in the R&S SMW.
® Startup R&S SZU100A System Requirements Protection of waveguide flanges Protect the waveguide flanges of the IQ upconverter against mechanical damage. Always use a torque wrench to tighten the screws of the waveguide flanges. Shield the waveguides from dust and moisture, and avoid scratching the contact surfaces.
® Startup R&S SZU100A Measurement Setup Electromagnetic interference (EMI) affects the measurement results To suppress generated electromagnetic interference: ● Only use the enclosed cables set, as the R&S SZU has been calibrated with these cables. You can find out the corresponding cable set by the serial number, which is the same as the serial number of the R&S SZU.
Page 21
® Startup R&S SZU100A Measurement Setup When setting up the measurement, it is recommended that you consider the following: ● Use only the supplied cables, as described in Electromagnetic interfer- ence (EMI) affects the measurement results. ● Connect the instruments in the given order. In particular, connect the baseband signals before starting up.
® Startup R&S SZU100A Starting Up 7. Before connecting to the DUT, configure the R&S SZU in the R&S SMW, see Starting With connecting USB, the R&S SMW recognizes the R&S SZU automatically. The R&S SMW reads all parameters for identification and the calibration table of the R&S SZU, and sets the optimum LO level.
Page 23
® Startup R&S SZU100A Starting Up 2. Select "I/Q OUT 1 > Config...". 3. Select "External Instrument > SZU (<Serial No> Bxxxx)". 4. Select "I/Q Output Type > Differential". Note: If you are working with an R&S SZU in each path, the R&S SMW only supports the single ended mode in both paths.
Page 24
® Startup R&S SZU100A Starting Up 5. Confirm with "Apply and Connect". The R&S SMW establishes the connection to the R&S SZU and shows the "Connections" tab. 6. Select "Check Connections". The R&S SMW checks the connections at the corresponding RF and I/Q con- nectors and displays the results.
Page 25
® Startup R&S SZU100A Starting Up 1 = see step 8 2 = see step 9 8. In the "System Configuration" dialog, check "Auto Connect". When enabled, the R&S SMW automatically (re)establishes the connection to the R&S SZU, e.g. after a restart or an instrument preset.
Page 26
® Startup R&S SZU100A Starting Up The overview tab shows all external instruments connected, in this case one connected R&S SZU. For more, see the user manual of the R&S SMW, chap- ter "System Configuration Settings", section "Overview". 11. Close the dialog.
Page 27
® Startup R&S SZU100A Starting Up 2. In the block diagram, select the checkbox in the "RF" to activate RF signal output. Figure 7-1: Display of one connected R&S SZU on the R&S SMW screen 1 = RF frequency of the R&S SZU RF output 2 = RF level, nominal level at the R&S SZU RF output (regulated level)
Page 28
® Startup R&S SZU100A Starting Up Two R&S SZU connected to the R&S SMW The R&S SMW supports one R&S SZU per path, i.e. you can connect another R&S SZU also to path B or vice versa. For the I/Q and RF ports of the two paths, the R&S SMW allows the following combinations: ●...
Page 29
® Startup R&S SZU100A Starting Up Figure 7-2: Overview tab with two connected R&S SZUs Manual 1425.3061.02 ─ 04...
® Startup R&S SZU100A Running Internal Adjustments Figure 7-3: R&S SMW screen with an R&S SZU in both paths Running Internal Adjustments To optimize the accuracy for the application with the R&S SZU, you can execute calibration routines directly in the R&S SMW.
Page 31
® Startup R&S SZU100A Running Internal Adjustments "SZU settings conflict: At least one adjustment has been done in another mode than the SZU is currently set to (single-ended / differential). Accuracy may be affected!" To adjust the R&S SZU ...
® Startup R&S SZU100A Behavior of the R&S SMW When Working with the R&S SZU The R&S SMW adjusts the internal calibration routines to the R&S SZU. "Adjust All" is disabled, i.e. in this configuration, you cannot execute adjust- ment routines for the R&S SMW.
Page 33
® Startup R&S SZU100A Behavior of the R&S SMW When Working with the R&S SZU The R&S SZU behaves as if it is an internal assembly. The following section outlines the behavior at the corresponding states. At startup or repeated plugging ●...
Page 34
® Startup R&S SZU100A Behavior of the R&S SMW When Working with the R&S SZU 1 = Frequency range with overrange enabled 2 = Frequency range with overrange disabled Note: The performance in the extended range can deviate from the specified values given in the data sheet.
Page 35
® Startup R&S SZU100A Behavior of the R&S SMW When Working with the R&S SZU At reboot ● If "Auto connect" is enabled, the R&S SMW establishes the connection auto- matically, provided the USB connection exists and the R&S SZU is assigned to an I/Q output ●...
® Remote Control of the R&S SZU R&S SZU100A Remote Control of the R&S SZU For description of the remote control commands required to connect and config- ure the connection between the R&S SZU in the R&S SMW, see the www.rohde-...
Page 37
® Remote Control of the R&S SZU R&S SZU100A When the R&S SZU is connected to the R&S SMW, the following remote control commands for the particular RF output are disabled also for the R&S SMW: ● "Analog Modulation Subsystems"...
® Glossary: List of Frequently Used Terms and Abbreviations R&S SZU100A Glossary: List of Frequently Used Terms and Abbreviations DUT: Device Under Test Glossary: List of the often used terms and abbreviations GUI: Graphical User Interface OS: Operating System OTA: Over The Air...
Page 39
® Glossary: List of Frequently Used Terms and Abbreviations R&S SZU100A USB: Universal Serial Bus. A standard type of connection for many different kinds of devices. Warm-up time: Minimum time the device needs to reach operating temperature and to adjust to the ambient temperature. The R&S SZU requires at least 30 minutes.
USB interface .......... 17 LO connection ......... 20 Waveguide flange ........13 LO in ............17 Welcome LO out ............17 SZU100A ..........8 Online help ..........6 Open source acknowledgment ....6 OSA ............6 Packaging material ........10 Power on ..........20 Power supply connector ......
Need help?
Do you have a question about the SZU100A and is the answer not in the manual?
Questions and answers