Start-up
Triggering in RUN mode
t
Cycle time
cyc
t
Trigger pulse
trg
width
t
Response time
delay
t
Processing time
proc
t
Output signal
out
20
Min. 33 ms
Min. 200 ms
Min. 1 ms
Max. 9 ms
Max. 27 ms
Max. 8 ms
Min. 15 ms
Operating Instructions, 10/2005 Edition, J31069-D1287-U001-A5-7418
For external lighting
For internal lighting
Smaller pulse widths are not
detected by the sensor as a trig-
ger.
For external lighting
For internal lighting
Image analysis
The output signal is reset with a
new trigger pulse. The signal
remains on for at least 15 ms.