Start-up

The four steps for (initial) start-up

1. Initial start-up

2. Teach model(s)
3. Test adjustments
4. Activate run mode
Initial start-up
This step automatically activates Welcome mode when you start up the
SIMATIC MV220 for the first time and after Reset All.
Requirements:
Color-mark sensor is connected (24 V DC)
You need the following tools:
A slot screw-driver Size 6 to 8 for adjusting the image at the adjustment
screw
Template 1 (black/white) and Template 2 (white) for image alignment
and ambient light compensation
Note before initial start up:
Note
The adjustment screw is designed to be difficult to move to prevent
misalignment as a result of vibration and shaking. Please do not over-
tighten the adjustment screw.
Note
Ensure that the templates completely fill the screen window and that
they lie as flat as possible and horizontally underneath the sensor.

SIMATIC MV220

Operating Instructions, 10/2005 Edition, J31069-D1287-U001-A5-7418
(Only for initial operation and after Reset All)
Start-up