FlatPAC-EN/EN MI Design Guide
FlatPAC-EN™ and FlatPAC-EN MI
EN Compliant Autoranging Switchers
Design Guide
and
"Quick Install" Instructions
www.vicorpower.com
Rev. 2/2012
Vicor 800-735-6200
Westcor Division 408-522-5280
Applications Engineering 800-927-9474

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FlatPAC-EN and is the answer not in the manual?

Questions and answers

Summary of Contents for VICOR FlatPAC-EN

  • Page 1 FlatPAC-EN/EN MI Design Guide FlatPAC-EN™ and FlatPAC-EN MI EN Compliant Autoranging Switchers Design Guide “Quick Install” Instructions www.vicorpower.com Rev. 2/2012 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474...
  • Page 2: Table Of Contents

    FlatPAC-EN/EN MI Design Guide TABLE OF CONTENT Overview of Product...........................3 Part Numbering...........................3 Mechanical Considerations.........................4 FlatPAC-EN/EN MI Do’s and Don’ts....................4 Technical Description.........................5 Configuration Layout drawing......................6 Quick Install Instructions........................7 Mechanical Drawings.........................10 Output connector information......................11 Connector Kit listing..........................12 Interface Connections.........................13 RS 232 Microcontroller........................14 Specifications............................18 Output vs.
  • Page 3: Overview Of Product

    Overview The FlatPAC-EN/EN MI is an ultra low profile switching power supply that provides up to 500 Watts from up to 4 isolated outputs. It operates on either 115 or 230 Vac nominal (47-63 Hz), or 250-380 Vdc. It can be populated with either VI-200/VI-J00 or Maxi/Mini/Micro Vicor converters.
  • Page 4: Mechanical Considerations

    2. For standard mounting (conduction cooling), use A1, A2, A3, A4, B1 and B2 mounting holes. 3. For a Vicor 2 Up FlatPAC retrofit replacement, use C1 and C2 as these two are identical to the recommended mounting holes on the FlatPAC.
  • Page 5: Technical Description

    FlatPAC-EN/EN MI Design Guide Technical Description The FlatPAC-EN/EN MI consists of an off-line single phase autoranging front end, EMI filter, customer interface, power supply control circuit, associated housekeeping circuits, a MiniHAM module and a selection of Vicor’s VI- 200/VI-J00 and/or Maxi/Mini/Micro DC-DC converters.
  • Page 6: Configuration Layout Drawing

    FlatPAC-EN/EN MI Design Guide FlatPAC-EN/EN MI Configuration Layout Rev. 2/2012 Pg 6 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474...
  • Page 7: Quick Install Instructions

    For standard mounting (conduction cooling), use A1, A2, A3, A4, B and B2 mounting holes. • For a Vicor 2 Up FlatPAC retrofit replacement, use C1 and C2 as these two are identical to the mounting holes on the FlatPAC.
  • Page 8 • Note: The molex connectors are limited to 9A/pin (27A per output) See page 11 for detailed diagrams of output connections. Sense Connections The FlatPAC-EN/EN MI is shipped with Autosense installed (For more informa- tion on Autosense, refer to page 16) STUD OUTPUT CONNECTORS...
  • Page 9 E/D-3 12 is +5VS. CBJ1-8 E/D-2 CBJ1-9 E/D-1 • For the FlatPAC-EN, CBJ1-2 and CBJ1-11 are not connected. CBJ1-10 CBJ1-11 • Use Molex mating receptacle #50-57-9412 with #16-02-0097 cinch pins. CBJ1-12 +5VS • Attach 24-30 AWG stranded wire using Molex tool #11-01-0209.
  • Page 10: Mechanical Drawings

    FlatPAC-EN/EN MI Design Guide FlatPAC-EN/EN MI Mechanical Drawings OUTPUT M1 OUTPUT M2 OUTPUT M1 OUTPUT M2 & M3 OUTPUTS M3 & M4 OUTPUTS M1 & M2 Rev. 2/2012 Pg 10 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474...
  • Page 11: Output Connector Information

    USE CRIMP TOOL: MOLEX (11-01-0197) Note: The type of output connector a FlatPAC-EN has depends on which modules are used. E.g. if a two output configuration uses two half bricks (instead of a full brick and half brick) this two output configuration will have the 18 pin molex connectors, not stud connectors.
  • Page 12: Connector Kit Listing

    FlatPAC-EN/EN MI Design Guide FlatPAC-EN - Connector Kit listing Connector Kit 19-130044 - Available for purchase from Westcor Rev. 2/2012 Pg 12 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474...
  • Page 13: Interface Connections

    Output Power Connections There are two types of output power terminals available in the FlatPAC-EN. Each slot has one of the following configurations: either 10-32 plated steel bolts or an 18 pin Molex connector (The type of output connector a FlatPAC-EN has depends on which modules are used.
  • Page 14: Rs 232 Microcontroller

    The operating mode setting is stored in a non-volatile EEPROM and requires an REON or REOFF command in order to switch modes. The default mode setting from the factory is in Manual mode. The FlatPAC-EN has an operating mode indicator LED, which is viewable through the left side vent hole nearest the CBJ1 E/D Interface Connector.
  • Page 15 FlatPAC-EN/EN MI Design Guide TON1, TON2, TON3, TON4 - Turn On commands for modules 1, 2, 3, or 4. These commands turn on the module identified by the trailing digit. If an automatic sequence is in effect at the time this command is received, a reply of "Inv Command" is returned; otherwise "OK" is returned.
  • Page 16 Sense mode when the Remote Sense connections are made. But in the event that the Remote Sense is not connect- ed or needed, no Local Sense selection is necessary - simply hook up the outputs and the FlatPAC-EN will auto- matically operate in Local Sense mode.
  • Page 17 FlatPAC-EN/EN MI Design Guide +Out +Sense Use 24-30 AWG Load Twisted Pair Wires -Sense -Out Figure 7: Remote Sense External Trim (Not applicable when using BatMod current source) The Trim pin can be used for external control of the output voltage. Trim connections on single and dual output connector for output M1 is J1-1 while for output M2 is J2-2.
  • Page 18: Specifications

    Primary to Chassis GND = 1,500 V Dielectric Withstand Primary to Secondary = 3,000 V Secondary to Chassis GND = 500 V * See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of normal output voltage. UTPUT VI-200/VI-J00 Modules Parameter MIN.
  • Page 19 FlatPAC-EN/EN MI Design Guide ’ UTPUT CONT Maxi/Mini/Micro Modules Parameter MIN. TYP. MAX. UNITS NOTES Setpoint Accuracy* ±1 % of V ±0.5 Load Regulation ±0.01 % of V See module design guide for e exact specifications. Temperature Regulation 0.002 0.005 %/°C...
  • Page 20: Output Vs. Ac & Dc Voltage Graphs

    FlatPAC-EN/EN MI Design Guide Output Power Derating Rev. 2/2012 Pg 20 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474...
  • Page 21 2. Also see Output Power vs. Input Voltage charts on page 21. 3. Please note that FlatPAC-EN configurations that uses Molex outputs connectors are limited to 9A/pin (27A per output). This is a Molex connector limitation, NOT a module power limitation. Westcor’s online configuration tool (VSPOC) will not provide a FlatPAC-EN/EN MI solution for requirements that exceed the 27A limitation.
  • Page 22: Thermal Curves

    FlatPAC-EN/EN MI Design Guide Thermal Curves for FlatPAC-EN/EN MI Rev. 2/2012 Pg 22 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474...
  • Page 23 FlatPAC-EN/EN MI Design Guide Thermal Curves for FlatPAC-EN/EN MI - continued Rev. 2/2012 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 Pg. 23...
  • Page 24 FlatPAC-EN/EN MI Design Guide Thermal Curves for FlatPAC-EN/EN MI - continued Rev. 2/2012 Pg 24 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474...
  • Page 25 FlatPAC-EN/EN MI Design Guide Thermal Curves for FlatPAC-EN/EN MI - continued Rev. 2/2012 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474 Pg. 25...
  • Page 26: Current Share Boards

    First developed by Westcor Engineering for parallel- Figure 1. CSB Interconnect Example ing MegaPAC supplies, the Box-to-Box Current Share Board or CSB allows two or more Vicor power Requirements: supplies to current share by utilizing the inherent voltage 1. For proper operation, the power supplies being paral- drop produced in the negative output return cable.
  • Page 27 FlatPAC-EN/EN MI Design Guide Current Share Boards - Optional Feature (contd) 0.13" (3.3mm) Dia Non Plated thru hole 4 places Molex CT43045F surface mountable connector. .390" height above board. 1.74" 1.500" (44.2mm) (38.1mm) J1 Pinout Description P ow e r - V 1 0.12"...
  • Page 28 FlatPAC-EN/EN MI Design Guide Notes Rev. 2/2012 Pg 28 Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474...
  • Page 29 Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. No license is grant- ed by implication or otherwise under any patent or patent rights of Vicor. Vicor components are not designed to be used in applications, such as life sup- port systems, wherein a failure or malfunction could result in injury or death.