ON delay timer : TD
n
LADDER EDITOR
X0
TD 0
n
Pro-H (LD)
X0
12
n
Pro-H (FBD)
X0
12
Single Shot timer : SS
n
LADDER EDITOR
X0
TD 0
n
Pro-H (LD)
X0
12
n
Pro-H (FBD)
X0
12
Note : MICRO-EH supports above 2 timers only.
Note : EH-150 supports Mono-stable timer "MS", integral timer "TMR" and Watch dog timer "WDT"
besides above ones.
TD 0
Y100
TD 0
0.1s
Y100
TD 0
Y100
0.1s
SS 0
Y100
SS 0
0.1s
Y100
SS 0
Y100
0.1s
12
0.1s
X0
TD 0
Y100
12
TC 0
* TC is a word data counting 0 up to 65,535.
12
0.1s
X0
TD 0
Y100
12
TC 0
* TC is a word data counting 0 up to 65,535.
19
1.2s
1.2s