CDVI V3E Installation Manual

CDVI V3E Installation Manual

Mortice electromagnets

Advertisement

Quick Links

V1ER
V3E
V3ER
V3E35R
V4E
V4ER
V5E
Mortice Electromagnets
EN
V1ER
V3E - V3ER
The installer's choice
cdvigroup.com
ENGLISH
V3E35R
V5SRB
V4E - V4ER
V5SRB
V5E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V3E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CDVI V3E

  • Page 1 ENGLISH V3E35R V1ER V3ER V5SRB V1ER V4E - V4ER V3E35R V4ER V5SRB V3E - V3ER Mortice Electromagnets The installer’s choice cdvigroup.com...
  • Page 2 The electromagnetic lock installed on emergency exits must be in accordance with the fire approval department (Ex: In France = NF 61-937). For more information, contact CDVI, the local fire officer or the safety officer responsible for the building.. * Depending on the version.
  • Page 3: Mounting Recommendations

    ® lock is recommended for use with power supplies manufactured by CDVI, however, other power supplies may be used on condition that they are of equivalent quality and characteristics rectified, filtered, regulated and protected by fuse in primary and secondary sectors.
  • Page 4: Optional Accessories

    INSTALLATION MANUAL V1ER - V3E - V3ER - V3E35R - V4E - V4ER - V5E Mortice Electromagnetic locks ELECTROMAGNETIC LOCK V3E - V3ER - V3E35R - V4E - V4ER - V5E Mortice Joggle Armature Roll pin Steel M5x8 magnetic bracket (excepted...
  • Page 5 INSTALLATION MANUAL V1ER - V3E - V3ER - V3E35R - V4E - V4ER - V5E Mortice Electromagnetic locks WITH BUILT-IN PCB BOARD DIRECT CONNECTION 12V DC VOLTAGE SELECTION White JUMPERS Green 12V dc 24V dc Black 24V DC White Green...
  • Page 6: Fault Finding

    INSTALLATION MANUAL V1ER - V3E - V3ER - V3E35R - V4E - V4ER - V5E Mortice Electromagnetic locks 7] FAULT FINDING PROBLEM POSSIBLE CAUSE SOLUTION - Check that the wires are connected to the right terminals. Door locking The lock is not receiving - Check that the power supply is compatible.
  • Page 7 MANUEL D’INSTALLATION V1ER - V3E - V3ER - V3E35R - V4E - V4ER - V5E Ventouse électromagnétiques encastrées cdvigroup.com...
  • Page 8 Reference : G0301EN0458V01 Extranet : EXE-CDVI_IM MORTICE MAGLOCKS CMYK A5 EN 01 *G0301EN0458V01* CDVI Group FRANCE (Headquarter/Siège social) Phone: +33 (0)1 48 91 01 02 Fax: +33 (0)1 48 91 21 21 CDVI CDVI FRANCE + EXPORT IBÉRICA Phone: +33 (0)1 48 91 01 02...

This manual is also suitable for:

V1erV3erV5eV4erV3e35rV4e

Table of Contents