Samsung DVM S AM100MXVDGH/ET Technical Data Book page 22

Vrf, dvm s for euro_et (r410a, 50hz, hp)
Hide thumbs Also See for DVM S AM100MXVDGH/ET:
Table of Contents

Advertisement

2. Specification
Essential
Type
Model Name
Outdoor unit module 1
Outdoor unit module 2
Outdoor unit module 3
Outdoor unit module 4
Wiring
Transmission Cable
connections
Remark
Power supply intake
Refrigerant
Type
Factory Charging
Sound
Sound Pressure
Sound Power
External
Net Weight
Dimension
Shipping Weight
Net Dimensions (WxHxD)
Shipping Dimensions (WxHxD)
Operating
Cooling
Temp. Range
Heating
NOTE
• Specification may be subject to change without prior notice.
• Specification comply with EN14511.
1) Capacities are based on (Equivalent refrigerant piping 7.5m, Level differences 0m);
- Cooling : Indoor temperature 27°C DB, 19°C WB / Outdoor temperature 35°C DB, 24°C WB
- Heating : Indoor temperature 20°C DB, 15°C WB / Outdoor temperature 7°C DB, 6°C WB
※ Eurovent certified
2) Allowed combination ratio of the total rated indoor unit capacity over the rated outdoor unit capacity is
50~130%.
3) Sound pressure level is obtained in an anechoic room.
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A-weighted sound pressure level
- Reference acoustic pressure 0 dB = 20uPa
4) Sound power level is an absolute value that a sound source generates.
- dBA = A-weighted sound power level
- Reference power : 1pW
- Measured according to ISO 3741
5) Sound values of multi combination are theoretical values based on sound results of individual installed units.
6) These products contain R410A (GWP=2,088) which is fluorinated greenhouse gas.
7) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.
(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether
the PDM kit should be installed or not.)
- PDM kit: Pressure Drop Modulation kit
When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local
dealer for more information.
• In case you want to know more information regarding capacity and correction, please refer to capacity table
TDB on pvi.samsung.com site.
22
mm
2
-
-
-
kg
tCO
e
2
Cooling
dB(A)
Heating
dB(A)
dB(A)
kg
kg
mm
mm
DVM S
AM380MXVDGH/ET
AM120MXVDGH/ET
AM120MXVDGH/ET
AM140MXVDGH/ET
-
0.75
F1, F2
Both indoor and outdoor unit
R410A
6.5 x 2 + 7.7 x 1
43.22
66
68
86
210.0 x 2 + 226.0 x 1
217.0 x 2 + 246.0 x 1
(880 x 1,695 x 765) x 2 +
(1,295 x 1,695 x 765) x 1
(948 x 1,887 x 832) x 2 +
(1,363 x 1,887 x 832) x 1
-5 ~ 48
-25 ~ 24
DVM S
AM400MXVDGH/ET
AM120MXVDGH/ET
AM140MXVDGH/ET
AM140MXVDGH/ET
-
0.75
F1, F2
Both indoor and outdoor unit
R410A
6.5 x 1 + 7.7 x 2
45.73
66
68
86
210.0 x 1 + 226.0 x 2
217.0 x 1 + 246.0 x 2
(880 x 1,695 x 765) x 1 +
(1,295 x 1,695 x 765) x 2
(948 x 1,887 x 832) x 1 +
(1,363 x 1,887 x 832) x 2
-5 ~ 48
-25 ~ 24