Samsung DVM S AM100MXVDGH/ET Technical Data Book

Samsung DVM S AM100MXVDGH/ET Technical Data Book

Vrf, dvm s for euro_et (r410a, 50hz, hp)
Hide thumbs Also See for DVM S AM100MXVDGH/ET:
Table of Contents

Advertisement

VRF
Technical
Data Book
DVM S for Euro_ET
(R410A, 50Hz, HP)
Model : Essential Type

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVM S AM100MXVDGH/ET and is the answer not in the manual?

Questions and answers

Summary of Contents for Samsung DVM S AM100MXVDGH/ET

  • Page 1 Technical Data Book DVM S for Euro_ET (R410A, 50Hz, HP) Model : Essential Type...
  • Page 2 History Version Modification Date Remark Ver. 1.0 Release DVM S Essential (R410A, 50Hz, HP) for Euro_ET TDB 16.12.19.
  • Page 3 Nomenclature Outdoor Unit Model Name Buyer (1) Classification (5) Feature 1 Inverter DVM S Eco (2) Capacity (6) Feature 2 x 1/10 HP (3 digits) Standard + General Temp.+ Module High EER + Low Temp. + Module High EER + General Temp. + Module Standard + General Temp.
  • Page 4 This ideal air conditioning system accomodates all variable environments, including large commercial or residential buildings. Samsung DVM S offers innovative features to benefit the indoor comfort as well operational coasts of the system through technological advances such as: The world’s largest capacity...
  • Page 5 Web-based remote monitoring and management system allows quick and easy HVAC control and breakdown alert. Eurovent Certified Performance Samsung DVM S had become the 1st VRF Product to be certified by Eurovent, the European Committee of HVAC&R, in March 2014.
  • Page 6: Table Of Contents

    Contents 1. Combination Table 2. Specification 3. Electric Characteristics 4. Dimensional Drawing 5. Center of Gravity 6. Electrical Wiring Diagrams 7. Sound Data 8. Operation Range 9. Piping Diagram 10. Installation 11. Accessory...
  • Page 7: Make Sure To Use An Indoor Unit That Is Compatible With Dvm S

    1. Combination Table Outdoor Units Essential System Model Capacity of Single Unit (HP) Capa Code No. of Modules 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP 10HP AM100MXVDGH/ET 12HP AM120MXVDGH/ET 14HP AM140MXVDGH/ET 16HP AM160MXVDGH/ET 18HP AM180MXVDGH/ET 20HP AM200MXVDGH/ET 22HP AM220MXVDGH/ET...
  • Page 8: Combination Table

    1. Combination Table Indoor Units Capacity (kW) Model 11.2 12.8 14.0 16.0 JSF-0 1Way JSF-1 JSF-2 2Way CST 4Way CST 360 CST Floor Standing Unit 4Way CST S (600X600) Duct S (MSP) Slim Duct MSP Duct Ceiling Console Boracay Boracay (with EEV) AR5000 AR5000 (with...
  • Page 9 1. Combination Table Indoor Units Capacity (kW) Model 22.0/ 1000 11.2 12.8 14.0 16.0 18.0 25.0 28.0 32.0 50.0 22.4 HSP Duct OAP Duct Big Duct Hydro Unit HE Hydro Unit HT ERV Plus NOTE • Make sure to use an indoor unit that is compatible with DVM S. •...
  • Page 10: External Appearance

    1. Combination Table External Appearance Essential Capa Capa Model Name Model Model Name Model [HP] [HP] AM140MXVDGH/ET AM100MXVDGH/ET AM160MXVDGH/ET AM120MXVDGH/ET AM180MXVDGH/ET AM200MXVDGH/ET AM260MXVDGH/ET AM220MXVDGH/ET AM300MXVDGH/ET AM240MXVDGH/ET AM280MXVDGH/ET AM320MXVDGH/ET AM380MXVDGH/ET AM340MXVDGH/ET AM360MXVDGH/ET AM400MXVDGH/ET...
  • Page 11: Specification

    2. Specification Essential Type DVM S DVM S DVM S Model Name AM100MXVDGH/ET AM120MXVDGH/ET AM140MXVDGH/ET Outdoor unit module 1 Outdoor unit module 2 Outdoor unit module 3 Outdoor unit module 4 Power Supply Ø, #, V, Hz 3, 4, 380-415, 50 3, 4, 380-415, 50 3, 4, 380-415, 50 Mode...
  • Page 12 When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information. • In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
  • Page 13 2. Specification Essential Type DVM S DVM S DVM S Model Name AM160MXVDGH/ET AM180MXVDGH/ET AM200MXVDGH/ET Outdoor unit module 1 AM100MXVDGH/ET Outdoor unit module 2 AM100MXVDGH/ET Outdoor unit module 3 Outdoor unit module 4 Power Supply Ø, #, V, Hz 3, 4, 380-415, 50 3, 4, 380-415, 50 3, 4, 380-415, 50 Mode...
  • Page 14 When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information. • In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
  • Page 15 2. Specification Essential Type DVM S DVM S DVM S Model Name AM220MXVDGH/ET AM240MXVDGH/ET AM260MXVDGH/ET Outdoor unit module 1 AM100MXVDGH/ET AM120MXVDGH/ET AM120MXVDGH/ET Outdoor unit module 2 AM120MXVDGH/ET AM120MXVDGH/ET AM140MXVDGH/ET Outdoor unit module 3 Outdoor unit module 4 Power Supply Ø, #, V, Hz 3, 4, 380-415, 50 3, 4, 380-415, 50 3, 4, 380-415, 50...
  • Page 16 When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information. • In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
  • Page 17 2. Specification Essential Type DVM S DVM S DVM S Model Name AM280MXVDGH/ET AM300MXVDGH/ET AM320MXVDGH/ET Outdoor unit module 1 AM140MXVDGH/ET AM120MXVDGH/ET AM140MXVDGH/ET Outdoor unit module 2 AM140MXVDGH/ET AM180MXVDGH/ET AM180MXVDGH/ET Outdoor unit module 3 Outdoor unit module 4 Power Supply Ø, #, V, Hz 3, 4, 380-415, 50 3, 4, 380-415, 50 3, 4, 380-415, 50...
  • Page 18 When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information. • In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
  • Page 19 2. Specification Essential Type DVM S DVM S Model Name AM340MXVDGH/ET AM360MXVDGH/ET Outdoor unit module 1 AM160MXVDGH/ET AM180MXVDGH/ET Outdoor unit module 2 AM180MXVDGH/ET AM180MXVDGH/ET Outdoor unit module 3 Outdoor unit module 4 Power Supply Ø, #, V, Hz 3, 4, 380-415, 50 3, 4, 380-415, 50 Mode HEAT PUMP...
  • Page 20 When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information. • In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
  • Page 21 2. Specification Essential Type DVM S DVM S Model Name AM380MXVDGH/ET AM400MXVDGH/ET Outdoor unit module 1 AM120MXVDGH/ET AM120MXVDGH/ET Outdoor unit module 2 AM120MXVDGH/ET AM140MXVDGH/ET Outdoor unit module 3 AM140MXVDGH/ET AM140MXVDGH/ET Outdoor unit module 4 Power Supply Ø, #, V, Hz 3, 4, 380-415, 50 3, 4, 380-415, 50 Mode...
  • Page 22 When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local dealer for more information. • In case you want to know more information regarding capacity and correction, please refer to capacity table TDB on pvi.samsung.com site.
  • Page 23: Electric Characteristics

    3. Electric Characteristics Essential Power Supply Voltage Range Capacity Running Current [A] Current [A] ODU Fan Motor Model Min. Max. Voltage Cooling Heating FLA [A] (-10%) (+10%) 28.0 AM100MXVDGH/ET 380-415 11.5 21.1 0.83 33.6 AM120MXVDGH/ET 380-415 14.8 0.83 40.0 AM140MXVDGH/ET 380-415 19.9 17.9...
  • Page 24: Dimensional Drawing

    4. Dimensional Drawing Outdoor unit • AM100~120MXVDGH Table of descriptions Remark Table of descriptions Remark Gas Ref. pipe See note 4. Power wiring conduit Φ44 Liquid Ref. pipe See note 4. Communication wiring conduit Φ22 Power wiring conduit Φ44 Knock-out Hole for Ref. Piping (bottom) Communication wiring conduit Φ34 Knock-out Hole for Ref.
  • Page 25 4. Dimensional Drawing Outdoor unit • AM140~180MXVDGH Table of descriptions Remark Table of descriptions Remark Gas Ref. pipe See note 4. Power wiring conduit Φ44 Liquid Ref. pipe See note 4. Communication wiring conduit Φ22 Power wiring conduit Φ44 Knock-out Hole for Ref. Piping (bottom) Communication wiring conduit Φ34 Knock-out Hole for Ref.
  • Page 26: Center Of Gravity

    5. Center of Gravity 5. Center of Gravity Outdoor unit • AM100~120MXVDGH Units : mm [inches] [2’-6”] [2’-5”] Model AM080∗∗∗∗∗∗ [1'-2 1/4"] [1'-6"] [1'-10"] AM100∗∗∗∗∗∗ [1'-2 1/4"] [1'-6"] [1'-10"] AM120∗∗∗∗∗∗ [1'-2 1/4"] [1'-6"] [1'-10"]...
  • Page 27 5. Center of Gravity Outdoor unit • AM140~180MXVDGH Units : mm [inches] 1150 [2’-6”] [3’-9 1/4”] Model AM140∗∗∗∗∗∗ [1'-2 1/2"] [1'-11"] [2'-4"] AM160∗∗∗∗∗∗ [1'-2 3/8"] [2'-1 3/4"] [2'-4"] AM180∗∗∗∗∗∗ [1'-2 3/8"] [2'-1 3/4"] [2'-4"]...
  • Page 28: Electrical Wiring Diagrams

    6. Electrical Wiring Diagrams Outdoor unit • AM100~140MXVDGH INV PBA1 Printed circuit board (inverter1) EEV1 Electronic expansion valve 1 LIQUID(10K) Thermistor (Liquid Tube Temp._10Kohm) INV PBA2 Printed circuit board (inverter2) EEV2 Electronic expansion valve 2 HOTGAS1 V/V Solenoid valve (Hot Gas Bypass1) EMI PBA1 Printed circuit board (emi1) EVI-OUT(10K)
  • Page 29 6. Electrical Wiring Diagrams Outdoor unit • AM160~180MXVDGH INV PBA1 Printed circuit board (inverter1) EEV1 Electronic expansion valve 1 LIQUID(10K) Thermistor (Liquid Tube Temp._10Kohm) INV PBA2 Printed circuit board (inverter2) EEV2 Electronic expansion valve 2 HOTGAS1 V/V Solenoid valve (Hot Gas Bypass1) EMI PBA1 Printed circuit board (emi1) EVI-OUT(10K)
  • Page 30: Sound Data

    7. Sound Data Summary Essential Capacity Sound Pressure dB(A) Sound Power Model dB(A) Cooling Heating 28.0 AM100MXVDGH/ET 33.6 AM120MXVDGH/ET 40.0 AM140MXVDGH/ET 45.0 AM160MXVDGH/ET 50.4 AM180MXVDGH/ET 56.0 AM200MXVDGH/ET 61.6 AM220MXVDGH/ET 67.2 AM240MXVDGH/ET 73.6 AM260MXVDGH/ET 80.0 AM280MXVDGH/ET 84.0 AM300MXVDGH/ET 90.4 AM320MXVDGH/ET 95.4 AM340MXVDGH/ET 100.8 AM360MXVDGH/ET...
  • Page 31: Sound Pressure Level

    7. Sound Data Sound Pressure level Unit: dB(A) Model Cooling Silent 1 Silent 2 Silent 3 Microphone AM100MXVDGH/ET AM120MXVDGH/ET 1.5m Front AM140MXVDGH/ET AM160MXVDGH/ET • NR Curve 1) AM100MXVDGH/ET 2) AM120MXVDGH/ET NR 90 NR 90 NR 85 NR 85 Cooling NR 80 Cooling NR 80 NR 75...
  • Page 32 7. Sound Data Sound Pressure level Unit: dB(A) Model Cooling Silent 1 Silent 2 Silent 3 Microphone AM180MXVDGH/ET 1.5m Front • NR Curve 1) AM180MXVDGH/ET AM180MXVDGH/ET NR 90 NR 85 NR 80 Cooling NR 75 NR 70 NR 65 Silent 1 Silent 2 NR 60 Silent 3...
  • Page 33 7. Sound Data Sound Power level Unit: dB(A) Model Power AM100MXVDGH/ET AM120MXVDGH/ET AM140MXVDGH/ET AM160MXVDGH/ET 1) AM100MXVDGH/ET 2) AM120MXVDGH/ET NR 90 NR 90 NR 85 NR 85 NR 80 NR 80 NR 75 NR 75 NR 70 NR 70 NR 65 NR 65 NR 60 NR 60...
  • Page 34 7. Sound Data Sound Power level Unit: dB(A) Model Power AM180MXVDGH/ET 1) AM180MXVDGH/ET AM180MXVDGH/ET NR 90 NR 85 NR 80 NR 75 NR 70 NR 65 NR 60 NR 55 NR 50 NR 45 NR 40 NR 35 NR 30 NR 25 NR 20 NR 15...
  • Page 35: Operation Range

    8. Operation Range 8. Operation Range Cooling Heating Continuous Warming Operation Range Continuous Operation Range Operation Range “Expand Operational Temperature Range” Option 25 27 Indoor(˚CWB) Indoor(˚CWB) (1) The operating range is shown in these figures (2) The assumed installation condtions are as follows - Outdoor units and indoor units combination - The Pipe length(including elbow) is 5m - The Level difference is 0m...
  • Page 36 8. Operation Range Defrosting correction factor The heating capacity tables do not take account of the reduction in capacity, when frost has accumulated or while the defrosting operation is in progress. The capacity values, which take these factors into account, in other words, the integrated heating capacity values, can be calculated as follows : Formula : A = B ×...
  • Page 37: Piping Diagram

    9. Piping Diagram 9. Piping Diagram Outdoor unit (1) AM100~120MXVDGH Ball Valve - Outdoor Fan Motor Gas pipe (BV_G) (OFM) Thermistor - Ambient (T_A) Thermistor - Cond Out (T_CO) Heat Exchanger - Main (HX_M) Thermistor - Suction pipe (T_S) Electronic Check Valve - Expansion EEV Bypass...
  • Page 38 9. Piping Diagram Outdoor unit (2) AM140~180MXVDGH Ball Valve - Outdoor Fan Motor 1 Outdoor Fan Motor 2 Gas pipe (BV_G) (OFM1) (OFM2) Thermistor - Ambient (T_A) Thermistor - Cond Out (T_CO) Heat Exchanger - Main (HX_M) Pressure Sensor - Low (PS_L) Electronic Check Valve -...
  • Page 39 9. Piping Diagram Cooling System • 18HP with indoor units...
  • Page 40 9. Piping Diagram Heating System • 18HP with indoor units ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑ ↑...
  • Page 41: Installation

    10. Installation Electrical wiring work • When installing outdoor units in module, select the power supply cable according to the sum of outdoor unit capacity. (Refer to the table for each model) • Power Supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed flexible cord.
  • Page 42: Electrical Wiring Work

    10. Installation Electrical wiring work Caution for electrical work • You must install ELCB or MCCB + ELB CAUTION - ELCB: Earth leakage breaker - MCCB: Molded case circuit breaker - ELB: Earth leakage breaker • Do not operate the outdoor unit before completing the refrigerant pipe work. •...
  • Page 43 10. Installation Electrical wiring work Power and communication cable configuration • Main power and the ground cable must be withdrawn through the knock-out hole on the bottom-right or right side of the cabinet. • Withdraw the communication cable from the designated knock-out hole on the bottom-right side of the front part. •...
  • Page 44 10. Installation Electrical wiring work <When the module combination is in the tables of "Outdoor unit combination"> Main unit Sub unit Sub unit ELCB MCCB+ Communication cable Power·ground cable Communication cable between outdoor units Power cable Protection tube Power/ground cable Specification of the protection tube Name Temper grade...
  • Page 45 10. Installation Electrical wiring work Specification of Cable and Connecting method f For communication cable, 2-core sheathed vinyl cable should be used which satisfies nominal area of 0.75~1.25mm2 thickness. If 2 or more than 3 communication are connected with one cable which is 4, 6 or more strands, communication malfunction could be caused.
  • Page 46 10. Installation Space requirement for installation f Space requirement was decided based on following conditions; Cooling mode, outdoor temperature of 35 °C. Larger space is required if the outdoor temperature is higher than 35 °C or if the place is heated easily by quantity of solar radiation.
  • Page 47 10. Installation Space requirement for installation Module installation Over 300 Height of the wall is Over 100 unlimited Over 100 Front side Front Over 400 Over 400 side Over 100 <Case 2> <Case 1> Over 100 Over 100 Over 100 Front side Over 100 Over 100...
  • Page 48 10. Installation Base construction and installation of the outdoor unit Examples of draining work f Construct the drainage ditch with reinforced concretes and make sure that water-proofing work is done. f For smooth draining of defrost water, make sure to apply 1/50 slope. f Construct a drainage around the outdoor unit to prevent the defrost water (from the outdoor unit) from stagnating, overflowing or freezing near the installation space.
  • Page 49 10. Installation Base construction and installation of the outdoor unit (Unit : mm) Classification DVM S Small Type DVM S Large A Type DVM S Large B type 1,350 1,350 1,150 1,150 Cautions regarding on connecting the anchor bolt X Tighten the rubber washer to prevent the bolt connection part of the outdoor unit from corroding. CAUTION Rubber washer f Anchor specification...
  • Page 50 10. Installation Wind/snow prevention duct Installing the outdoor unit around the obstacles f It is necessary to install a discharge guide duct(field supply) to direct exhaust from the fan horizontally, when it is difficult to provide a minimum space of 2m between the air outlet and a nearby obstacle. Discharged air Upper floor Discharged air...
  • Page 51 10. Installation Wind/snow prevention duct Installing the outdoor unit in windy region f In windy regions such as near sea shores, protection wall or wind protection duct must be installed for normal operation of the outdoor unit. (Refer to the illustration of the snow prevention duct, for installing the wind protection duct.) f Install the wind prevention duct with the consideration of major wind direction.
  • Page 52: Refrigerant Pipe Installation

    10. Installation Refrigerant pipe installation Refrigerant pipe work f The length of refrigerant pipe should be as short as possible and the height difference between an indoor and outdoor unit should be minimized. f Piping work must be done within allowable piping length, height difference, and the allowable length after branching.
  • Page 53 10. Installation Refrigerant pipe installation Selecting refrigerant pipe First branch joint Increase the main pipe size f Install the refrigerant pipe according to main pipe size of each outdoor unit capacity. f When the pipe length (including elbow) between an outdoor unit and the farthest indoor unit exceeds 90m, you must increase the size of the pipe (main pipe) by one grade which connects between the outdoor unit to the first branch joint.
  • Page 54 10. Installation Refrigerant pipe installation Size of the pipe connected to the outdoor unit (A) Select the size of the main pipe according to the below table. *Maximum pipe length within 90m *Maximum pipe length over 90m Outdoor unit capacity (kW) (Cooling) Liquid pipe (mm) gas pipe (mm)
  • Page 55 10. Installation Refrigerant pipe installation Size of the pipe between branch joints (B) Select the pipe size according to the sum of indoor unit capacity which will be connected after the branch. ❇ However, if the size of the pipe between branch joints (B) is bigger than the size of the pipe connected to the ❇...
  • Page 56 10. Installation Refrigerant pipe installation 33.6 kW 40.0 kW 61.6 kW Branch joint f Branch joint between outdoor units (C) Classification Model name Specification (kW) MXJ-TA3419M 135.2 kW and below Y-joint for outdoor unit (C) MXJ-TA4122M Over 135.2 kW f First branch joint (D) Make a selection according to outdoor unit capacity.
  • Page 57 10. Installation Refrigerant pipe installation f Branch joint (E) Select a branch joint according to the sum of indoor unit capacity which will be connected after the branch. ❇ However, if the size of the pipe between branch joints (E) is bigger than the size of the pipe connected to the ❇...
  • Page 58 10. Installation Refrigerant pipe installation 33.6 kW 40.0 kW 61.6 kW Ex.) 135.2 kW Pipe size (mm) Capacity (kW) Low pressure High pressure Liquid pipe gas pipe gas pipe 33.6 kW Ø 12.70 Ø 28.58 Ø 19.05 73.6 kW Ø 19.05 Ø 34.92 Ø 28.58 135.2 kW Ø...
  • Page 59 10. Installation Refrigerant pipe installation Size of the pipe between branch joints (B) Select the pipe size according to the sum of indoor unit capacity which will be connected after the branch. ❇ However, if the size of the pipe between branch joints (B) is bigger than the size of the pipe connected to the ❇...
  • Page 60 10. Installation Refrigerant pipe installation 33.6 kW 39.2 kW 44.8 kW Branch joint f Branch joint between outdoor units (C) Classification Model name Specification (kW) MXJ-TA3419M 135.2 kW and below Liquid/Low pressure Y-joint MXJ-TA4122M Over 135.2 kW MXJ-TA3100M 135.2 kW and below High pressure Y-joint (C) MXJ-TA3800M Over 135.2 kW f First branch joint (D)
  • Page 61 10. Installation Refrigerant pipe installation Additional refrigerant 46.4 kW 61.6 kW (33.6 kW + 28.0 kW) Ø12.70 (5 m) Ø9.52 (1m) Ø12.70 (5 4.5 kW Ø15.88 (10 Ø12.70 (5 m) Ø6.35 (5 m) Ø 1 2 . 7 0 5.6 kW Ø12.70 (10 m) Ø12.70 (5 Ø6.35 (10 m) Ø6.35(15 m)
  • Page 62 10. Installation Refrigerant pipe installation Refrigerant pipe installation f Basic amount of refrigerant within the outdoor unit (kg) - Amount of additional refrigerant has to be calculated based on the sum of all liquid pipe length. Classification AM080JXVHGH/EU AM100JXVHGH/EU AM120JXVHGH/EU AM140JXVHGH/ET AM160JXVHGH/ET AM180JXVHGH/ET...
  • Page 63 10. Installation Refrigerant pipe installation f Amount of additional refrigerant for each indoor unit (ⓑ) (Unit : kg) Capacity (kW) 1000 1 .5 1 .7 2 .2 2 .8 3 .2 3 .6 4 .5 5 .6 7 .1 8 .2 9.3 11 .2 12 .8 14 22 22 .4 28 Model...
  • Page 64 10. Installation Refrigerant pipe installation f Method to calculate total amount of additional refrigerant - Amount of additional refrigerant depending on the pipe length (ⓐ) - Amount of additional refrigerant for each indoor unit (ⓑ) = ∑(Amount of additional refrigerant for each connected indoor unit) ❇...
  • Page 65 10. Installation Refrigerant pipe installation Number Unit amount of Amount of additional Total amount of Model name of of units refrigerant (kg/EA) refrigerant (kg) additional refrigerant (kg) Classification indoor unit ∑(①×②) ① ② ①×② 4way cassette 0.45 2.25 (AM071FN4DEH✴) 4way cassette 0.57 1.14 Indoor unit...
  • Page 66 10. Installation Refrigerant pipe installation Additional refrigerant Pipe installation between the outdoor units f You will need branch joints, which is an optional accessory, for connecting in between outdoor units in order to combine outdoor units in module. ❇ For optimal distribution of the refrigerant, you must use Y-joint as branch joint for connecting outdoor units. ❇...
  • Page 67 10. Installation Refrigerant pipe installation Examples of refrigerant pipe installation 1. Using Y-joint 2. Using distribution header Using Y-joint Note 1) Note 1) Direct-connected indoor unit without MCU (for HR only) - This indoor unit can only be used for cooling operation. (Heating operation is not possible.) - Connect indoor unit to liquid and low pressure gas pipe.
  • Page 68 10. Installation Refrigerant pipe installation Allowable length of the refrigerant pipe and the installation examples Classification Single Installation Module installation Outdoor unit Outdoor unit Branch joint Branch joint Installing only with Y-joint Indoor unit Indoor unit Outdoor unit Distribution header Outdoor unit Branch joint Distribution...
  • Page 69 10. Installation Refrigerant pipe installation Classification Example Remarks Installing only with a+b+c+d+e+f+g+p ≤ 200m Y-joint 200m(220m) Equivalent Actual length a+b+h ≤ 200m (220m), length below Installing with Y-joint Y-joint: 0.5 m, (Equivalent (220m and distribution header a+i+k ≤ 200m (220m) Distribution length) header: 1 m...
  • Page 70 10. Installation Refrigerant pipe installation Electrical wiring work EEV kit Model name Remarks MEV-E24SA 1 indooor MEV-E32SA MXD-E24K132A MXD-E24K200A 2 indooor EEV kit ~ Actual pipe Apply to products without EEV MXD-E32K200A Indoor unit length (Wall mount & ceiling) 20 m or less MXD-E24K232A MXD-E24K300A 3 indooor...
  • Page 71 10. Installation Refrigerant pipe installation Classification Installation with Y-joint Installing with MCU only Direct-connected indoor unit without MCU (Cooling only) (Connecting Only Low Pressure Gas Pipe / Liquid Pipe note 3) Installing with MCU and Y-joint Classification Example Remarks Installing only Equivalent a+g+j ≤...
  • Page 72 10. Installation Refrigerant pipe installation Classification Example Remarks Outdoor unit ~ 110 m / 110 m H1 ≤ 110 m / 110 m Note 1) Indoor unit 40 m or less H2 ≤ 40 m Indoor unit ~ Maximum But, when AM∗∗∗∗NQDEH∗ / AM∗∗∗JNV∗ is installed, Indoor unit allowable H2 is 15 m or less.
  • Page 73 10. Installation Refrigerant pipe installation Note 1) When indoor unit is located at higher level than outdoor unit, allowable height difference is 110m, (If the height difference is over 40m, contact your local dealer for more information.) but when the indoor unit is located at lower level than outdoor unit, allowable height difference is 110m (If the height difference is over 50m, need to decide whether to install PDM kit or not.) Model name of the PDM kit : MXD-A38K2A, MXD-A12K2A, MXD-A58K2A...
  • Page 74 10. Installation Refrigerant pipe installation Installing the MCU MCU specification Model MCU-S6NEK2N MCU-S4NEK3N MCU-S2NEK2N MCU-S1NEK1N Exterior of MCU Number of connectable indoor Up to 8 units Up to 8 units Up to 8 units Up to 8 units units at one port The maximum capacity of the 16 kW...
  • Page 75 10. Installation Refrigerant pipe installation Installing the indoor units Model MCU-S6NEK2N MCU-S4NEK3N MCU-S2NEK2N MCU-S1NEK1N Example installing (Each port connection) MCU series connection Example installing (MCU series connection) Under 16.0 kW indoor unit : Don’t use Y-connector This unit is only 16.0 kW ~ 28.0 kW indoor unit : Use Y-connector at the Gas &...
  • Page 76 10. Installation Refrigerant pipe installation How to connect the pipes Protect with wet towel when welding 70 mm Pipe connection from outdoor unit ← Default installing direction. Low pressure gas pipe conection (welding) High pressure gas pipe connection (welding) Liquid pipe connection (welding) Pipe connection to indoor unit Liquid pipe (welding)
  • Page 77 11. Accessory Controller Classification Product Model Image Remark Using Wireless Remote MR-EH00 DVM, CAC Controller Wireless Remote AR-KH00E 360 CST Only DVM, CAC Controller Wired Remote MWR-WE11N DVM, CAC Controller Wired Remote Controller MWR-SH00N DVM, CAC - Simple Type Wired Remote Controller MWR-SH10N DVM, CAC...
  • Page 78 11. Accessory Controller Classification Product Model Image Remark Using Onoff Controller MCM-A202DN DVM, CAC Touch Centralized MCM-A300N DVM, CAC Controller WIFI KIT MIM-H03N DVM, CAC Centralized Control System Interface Module MIM-N01 DVM, CAC ERV Interface MIM-N10 DVM, CAC Module DMS2.5 MIM-D01AN DVM, CAC Integrated...
  • Page 79 Operation Mode MCM-C200 Selection Switch Others Module Controller MCM-A00N CHILLER Only CHILLER FCU Interface MIM-F10N CHILLER Only CHILLER Module NOTE • In case you want more information about the accessories, please refer to the control and accessories TDB on pvi.Samsung.com site.
  • Page 80 DVM, CAC Test run Solution External Room Sensor MRW-TA MRW-TA DVM, CAC Others Operation Mode Selection Switch MCM-C200 MCM-C200 NOTE • In case you want more information about the accessories, please refer to the control and accessories TDB on pvi.Samsung.com site.
  • Page 81 MXD-E32K200A MXD-E24K232A MXD-E24K300A 3 Indoor MXD-E32K224A MXD-E32K300A MXD-A38K2A 8~12 HP PDM KIT MXD-A12K2A 14~16 HP MXD-A58K2A 18~26 HP NOTE • In case you want more information about the accessories, please refer to the control and accessories TDB on pvi.Samsung.com site.
  • Page 82: Indoor Unit

    11. Accessory Indoor unit Product Image Model Remark PC1NUSMAN 1Way CST (JSF-1) PC1NUPMAN 1Way CST (JSF-1) (Z-sliding) PC1MWSKAN 1Way CST (JSF-0) PC1NWSMAN 1Way CST (JSF-1) PC1BWSMAN 1Way CST (JSF-2) PC2NUSMEN 2Way Cassette PC4SUSMAN 4Way Cassette S (600x600) (Waffle) PC4SUSMEN 4Way Cassette S (600x600) (Classic) PC4NUSKAN 4way Cassette S (Waffle) Panel...
  • Page 83 MCM-D201N A64K100E A64K100E A64K100E A64K100E MXD-A64K100E X 1 EA X 2 EA X 3 EA X 4 EA NOTE • In case you want more information about the accessories, please refer to the control and accessories TDB on pvi.Samsung.com site.
  • Page 84 5Hp's AHU MXD-K075AN only for 7.5Hp's AHU AHU-KIT MXD-K100AN only for 10Hp's AHU only for 10~40Hp's MCM-D201N NOTE • In case you want to know more information the accessories, please refer to the control and accessories TDB on pvi.samsung.com site...
  • Page 85 Ver.1.0 Samsung Electronics Co., LTD. B2B PM / SE Head Office (Suwon Korea) 129, Samsung-Ro, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 16677 Website : www.samsung.com, http://btsp.samsunggsbn.com Email : airconditioner@samsung.com Images and data in this book may subject to change without prior notice.