Summary of Contents for Neptune Technology HP Fire Service
Page 1
ARB® UTILITY MANAGEMENT SYSTEMS™ WATER ELECTRIC HP Fire Service Turbine Installation and Maintenance Guide...
Page 2
ARB® UTILITY MANAGEMENT SYSTEMS™ WATER ELECTRIC HP Fire Service Turbine Installation and Maintenance Guide...
Page 3
This manual is an unpublished work and contains the trade secrets and confidential information of Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of Neptune Technology Group Inc.
CONTACTING TECHNICAL SUPPORT If you encounter any problems with the installation or operation of your HP Fire Service Turbine, please call Neptune at (334) 283-6555 or 1-800-645-1892 and ask to speak with Customer Support.
Page 7
........................................HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE...
CHAPTER INSTALLATION INSTRUCTIONS This chapter is designed to take you through the installation process for the HP Fire Service Turbine. INSTALLATION INSTRUCTIONS The HP Fire Service Turbine meter will operate more accurately and reliably if installed and maintained properly. Fire Service Turbine meter performance is directly related to the flow conditions of the water entering the turbine measuring element.
After installation, it is important that the upstream (inlet) valve be put in the “full open” position during service. All throttling should be done only on the downstream (outlet) side of the meter HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE...
CHAPTER MAINTENANCE If you find that your HP Fire Service Turbine is not operating as expected when installed, use the following guidelines to try to determine the source of the problem. MAINTENANCE INSTRUCTIONS TURBINE When maintenance is necessary, the complete unitized measuring element (UME) may be quickly and easily interchanged with a factory-calibrated unit by following these steps: Close both the inlet and outlet gate valves.
Strainer is equipped with a flushing port and open bottom basket for removal of sediment. In addition, strainer may be equipped with a “blow-down valve” to facilitate easier cleaning HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE...
Page 12
........................................HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE...
Page 13
........................................HP FIRE SERVICE TURBINE INSTALLATION AND MAINTENANCE GUIDE...