Advertisement

LCS Sprayer
Operator's & Parts Manual
4-1-18 02-025R7
Printed In The USA — Specifications & Design Subject To Change Without Notice!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LCS Sprayer and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wylie LCS Sprayer

  • Page 1 LCS Sprayer Operator’s & Parts Manual 4-1-18 02-025R7 Printed In The USA — Specifications & Design Subject To Change Without Notice!
  • Page 2 Limited Warranty This is a limited warranty. It covers products manufactured by WYLIE Mfg. Co. The Warrantor is WYLIE Mfg. Co., 702 E. 40th St., Lubbock, Texas 79404 USA. The duration of the warranty for WYLIE manufactured equipment and products (excluding polyethylene tanks) is for one year from date of delivery to the carrier.
  • Page 3 Owner Registration Wylie Manufacturing Company 702 E. 40th St. Lubbock, TX 79404 Ph. 88-788-753 LCS Sprayers Date of Purchase Model Number Type of Applicator: Tank Serial Number Vegetable Cotton Trailer Serial Number Wheat Pasture Pump Model Other Wylie Invoice Number Owner’s Name...
  • Page 5: Table Of Contents

    Table of Contents Table Of Contents Safety Issues ................................2 - 3 Safety Decals & Placement ............................4 Introduction ................................... 5 Inspection & Setup ..............................6 - 8 Sprayer Operation ..............................9 - 13 Tip Charts ................................10 - 11 Maintenance ................................14 Troubleshooting Guidelines ............................
  • Page 6: Safety Issues

    Do not operate sprayer until this manual has been read and understood! Thoroughly read and understand all instructions before operating this sprayer. If you have questions, (888) 788-7753. please contact Wylie Manufacturing, 702 E. 40th St., Lubbock, TX 79404, Wylie Spray Center. You can also contact your nearest Place a “Slow Moving Vehicle”...
  • Page 7: Safety Issues

    Safety Issues After Use Inspect sprayer for wear or damage. Ensure that all fasteners and fittings are tight. Flush tank and pump with fresh water. Dispose of flush water using appropriate means. Carry out maintenance and/or lubrication procedures as outlined in this manual. Always Keep hands, feet and clothing away from moving parts.
  • Page 8: Safety Decals & Placement

    Safety Issues Safety Decals & Placement LCS Sprayers Decal #V9055 Decal #SW701W Decal #SW700...
  • Page 9: Introduction

    Introduction The Wylie LCS Sprayers are the result of years of testing and field proven experience. They are built of the finest ma- terials and expert workmanship to provide you with years of reliable service. The LCS Stockman Special Sprayer is available with a 300 gal.
  • Page 10: Inspection & Setup

    Inspection & Setup If your sprayer is equipped with the direct coupled pump, Your Wylie Power Sprayer was manufactured to the high- make sure that the chain is attached to the frame of the est standards of quality. It is necessary though, to check tractor to prevent rotation of the pump.
  • Page 11: Inspection & Setup

    Inspection & Setup It may be necessary to partially close the agitator ball valve in order to set the proper pressure. A fully open agitator valve may prevent sufficient fluid to be available for ad- equate pressure. Maximum pressure for the 7560 Hypro pump is 300 psi. Maximum pressure for the CDS/John Blue gear pump Figure A4 is 200 psi.
  • Page 12 Valve Valve Figure A9 LCS Control with Extender Boom The LCS sprayer may also be equipped with an electric Figure A7 control valve that can be operated from the tractor cab. A Extender Boom variety of electric control systems are available. A typical...
  • Page 13 Operation Operation Trigger Gun Operation Proper clothing, gloves, face protection and respirator (if needed) must be worn any time Never point the trigger gun at any part of your chemicals are handled. Failure to do so risks body. The high fluid pressure and/or chemical exposure, serious injury and possibly death.
  • Page 14 TeeJet Catalog or Wylie web nozzle may need to be installed. Contact a Wylie Spray site (www.wyliesprayers.com.) Center for assistance in sizing the proper TeeJet tips to *Clean the tip strainers on the Extender boom maintain uniform application.
  • Page 15 Tip Charts Boom Buster Spray Tip Chart ¼ " ¼ " " ½ " ¾ " ¾ " " TeeJet Broadcast Spray Tip Chart TP 110°/ 80° 20" TIP SPACING ALL VALUES BASED ON WATER FOR OTHER LIQUIDS SEE USEFUL FORMULAS AND CONVERSIONS 9.5 10.0 10.5 11.0 11.5 12.0 psi gpm 20 0.14...
  • Page 16 Operation Ground Drive LCS Operation Attach the fill hose from the nurse trailer to the Quick-Fill fitting, close the pump valve and open the Quick-Fill valve. Add the desired amount of chemical solution, then close the The LCS-800GD is equipped with a ground drive CDS/John Quick-Fill valve before disconnecting the fill hose.
  • Page 17 It is important to make sure that the spray tips can handle the volume and speed that is desired. Check the tip charts for tip performance. Call Wylie Customer Service for as- Pressure Release Lever > sistance in selecting additional spray tips.
  • Page 18: Maintenance

    Maintenance Maintenance Line Strainer Cleaning In order to clean the “Boom Buster” nozzles, remove the nozzle from the stand. Use compressed air to blow debris from the nozzle. Do not use pocket knives, wire or screw- drivers. Chemically resistant rubber gloves must be worn End of Day Procedure when cleaning the line strainer.
  • Page 19: Troubleshooting Guidelines

    (3) Clean strainer screen spray solution (3) Plugged strainer (4) See pump owners manual or contact (4) Malfunctioning pump Wylie Spray Center (1) Fill tank (2) Open ball valve (1) Spray tank low; air getting in pump (3) Clean strainer screen...
  • Page 20: Hypro Pump Information

    Pump Information Hypro Pump Information...
  • Page 21 Pump Information Hypro Pump Operation & Maintanence Con’t.
  • Page 22 Pump Information...
  • Page 23 Pump Information...
  • Page 24 Pump Information...
  • Page 25 Pump Information...
  • Page 26: Notes

    Notes <Notes>...

Table of Contents

Save PDF