I need to reupholster a fx920l exam chair and how to remove the upholstered part from the chair

Subscribe to Our Youtube Channel

Summary of Contents for Reliance FX920

  • Page 1 INSTALLATION AND OPERATING INSTRUCTIONS OWNERS MANUAL MODEL FX920 LOW VOLTAGE CONTROL CHAIR...
  • Page 2 For your future reference, mark the serial number in the space provided. QUALITY MANAGEMENT SYSTEM REGISTERED TO ISO 9001 ISO 13485 MADE IN AMERICA Reliance® Medical Products, Inc. • 3535 Kings Mills Road • Mason, Ohio 45040-2303 • 1-800-735-0357 • www.reliance-medical.com...
  • Page 3: Table Of Contents

    3.5. Memory Feature..........10 Chair Base Assembly..........22 Programming the Memory Feature......10 Lift Assembly............24 3.6. Revolving/Rotation........10 #26 Headrest Assembly.........26 3.7. Arm Movement..........11 Wiring Diagram - FX920 ........28 3.8. Footrest............11 LIMITED WARRANTY.............31 3.9. Headrest............11 Operation-No. 26 Headrest........11 Adjustment-No. 26 Headrest........11 4. PROGRAMMING THE CHAIR........12...
  • Page 4: Important Information

    -30 to +60º C Dangerous Voltage / Shock Hazard Relative Humidity: Operating: 5 to 95% without condensation Storage: 10 to 100% including condensation Fuse Rating Specification Atmospheric Pressure: Operating: 700hPa - 1060hPa Storage: 500hPa - 1060hPa Protective Earth Ground Burn Hazard/Hot Surface IN-FX920...
  • Page 5: Introduction

    : Ayez toujours le numéro de modèle et le numéro de série à portée de la “WARNING”- THE WARNING SYMBOL main avant de contacter Reliance® ou votre IDENTIFIES SPECIAL INSTRUCTIONS OR distributeur Reliance® autorisé. PROCEDURES WHICH, IF NOT CORRECTLY FOLLOWED, COULD RESULT IN PERSONAL “CLASSIFIED BY CANADIAN STANDARDS...
  • Page 6: Technical Specifications

    Equipment Model energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices Low Voltage Chair FX920 in the vicinity. However, there is no guarantee that interference Volts Hertz Amps will not occur in a particular installation.
  • Page 7: Installation

    REMARQUE : Si cette chaise est achetée avec both base clamping boards. un support à instruments Reliance®, le câble de commande de la chaise fourni permettra un fonctionnement adéquat. Se référer au manuel du 2.1.1.2. It is recommended that the skid be positioned as support d’instrument pour savoir comment faire la...
  • Page 8: Chair Lift

    Footswitch are programmable. By design, the instructions. motion of the Chair will STOP when either of these switches is released. If you want the motion of the Chair to CONTINUE after either of these switches is released, then see Section 4 for programming instructions. IN-FX920...
  • Page 9: Chair Top

    CONTINUE lorsque l’un ou l’autre de ces interrupteurs est relâché. Si vous désirez que le mouvement de la chaise S’ARRÊTE, après que l’un ou l’autre de ces interrupteurs est relâché, consultez la section 4 pour connaître les instructions de programmation. IN-FX920...
  • Page 10: Automatic Return

    The LED’s will stop blinking. Then press the RECLINE Switch which is programmed for memory mode. (Specify which RECLINE Switch will utilize this feature.) The switches will blink and the chair will recline on its own and stop at the programmed point. IN-FX920...
  • Page 11: Arm Movement

    When fully retracted the footrest will stay in place. 3.9. Headrest BLACK DOT 3.9.1. The No. 26 headrest is the standard headrest for the Model FX920 Chair. ACTUATOR WARNING- IF THE NO. 26 HEADREST RECEIVES A IMPACT OR STRIKES AN OBJECT WITH FORCE CONTACT RELIANCE®...
  • Page 12: Programming The Chair

    4.2.4.3 A one second beep will be heard to indicate the chair has EXITED Setup Mode. The LED’s will come back on. 4.2.1 These individual switches may be programmed to function in two ways. If the movement of the chair STOPS IN-FX920...
  • Page 13: Beep-On-Switch Feature

    IN-FX920...
  • Page 14: To Program The Home Mode Feature

    RAISE BASE switch at any time when the chair lift is not all the way down. NOTE: The Home Feature and Memory Feature can only be operated with the Base down and the Back fully upright See Section 3.5.2 Step 4 IN-FX920...
  • Page 15: Fuse Replacement

    Fuse Drawer into the AC Input Module without fuses. PRÉCAUTION : Pour éviter que le tiroir à fusible reste bloqué dans le module d’entrée CA, n’installez jamais le tiroir à fusible à l’intérieur du module d’entrée CA sans fusibles. IN-FX920...
  • Page 16: Troubleshooting Guide

    CHAIR TOP "WOBBLES" ON LOCK NUT IS LOOSE. 1) TIGHTEN LOCK NUT. CHAIR BASE ( UNDER SEAT BOARD.) MEMORY SYSTEM NOT PROGRAMMED PROPERLY. 1) SEE SECTION 3.5.1 OR SECTION INOPERATIVE. LOOSE CONNECTIONS UNDER CHAIR 2) CHECK ALL WIRING SEAT. CONNECTIONS. IN-FX920...
  • Page 17: Cleaning And Maintenance

    A V E R T I S S E M E N T : S E R É F É R E R these solvents could seriously damage such AUX DIRECTIVES LOCALES OU DES areas. PROFESSIONS DE LA SANTÉ POUR SÉLECTIONNER DES PRODUITS DE CONTRÔLE D’INFECTION EFFICACES. IN-FX920...
  • Page 18: Parts List

    Should your Exam Chair not perform properly, or if replacement parts are needed, contact the Reliance® Distributor, where you purchased this product or contact the Technical Service Department, Reliance® Medical Products, Inc., 3535 Kings Mills Road, Mason, Ohio 45040-2303, or call (800) 735-0358.
  • Page 19: Model Fx920 Chair Assembly

    Back Board Assembly** 1761173 Upholstered Center Assembly** 1761273 Upholstered Back Assembly** 1761373 Upholstered Arm Assembly** 1779273 Seat Board Assembly** 1765073 Scuff Pad** ** Please specify upholstery color when ordering. To order complete Upholstery Set use P/N. 1782073 Upholstery Set - FX920 IN-FX920...
  • Page 20: Chair Top Assembly

    FIGURE 7 CHAIR TOP ASSEMBLY IN-FX920...
  • Page 21 Spring, Plunger 1483995 Lock Block 1842692 Armrest Link Assembly - RH 1484095 Lock Shaft, Swivel 1842792 Armrest Link Assembly - LH 1762985 Actuator Mount Weld Assembly 2260599 .50 ID Thrust Washer 0561799 Lock Cam *Please specify paint color when ordering. IN-FX920...
  • Page 22: Chair Base Assembly

    FIGURE 8 CHAIR BASE ASSEMBLY 3, 4 30, 17 30, 17 16, 17 40, 39 IN-FX920...
  • Page 23 To order complete Base Assembly use P/N’s. 2715292 Chair Base Assembly - Low - 120V* 2715392 Chair Base Assembly - High - 120V* 2715492 Chair Base Assembly - Low - 220-240V* 2715592 Chair Base Assembly - High - 220-240V* *Please specify paint color when ordering. IN-FX920...
  • Page 24: Lift Assembly

    FIGURE 9 LIFT ASSEMBLY 33 & 37 IN-FX920...
  • Page 25 Pin - Roll (in Item 12) 1060392 Tubing Assembly 0422899 Disc - Valve 1183592 Piston Rod - High 1183692 Piston Rod - Low To order complete Lift Assembly use P/N’s. 2721192 Lift Assembly - High 2721292 Lift Assembly - Low IN-FX920...
  • Page 26: Headrest Assembly

    FIGURE 10 #26 HEADREST ASSEMBLY IN-FX920...
  • Page 27 144060 #26 Headrest Assembly* 2721692 Middle Joint Screw Assembly Includes: Item’s 5, 6, 7 & 8. *Please specify paint color when ordering. 2721792 Bottom Joint Screw Assembly ** Please specify upholstery color when ordering. Includes: Item’s 5, 6, 8 & 18 IN-FX920...
  • Page 28: Wiring Diagram - Fx920

    FIGURE 10 WIRING DIAGRAM - FX920 IN-FX920...
  • Page 29 IN-FX920...
  • Page 30 IN-FX920...
  • Page 31: Limited Warranty

    LIMITED WARRANTY The Reliance® product must be used only for the purposes and in the manner described in the literature distributed with the product. The products are warranted against defective materials and workmanship for a period of one (1) year from date of installation. Products or parts thereof will be repaired or replaced as required at Reliance®...
  • Page 32 MADE IN AMERICA Reliance MEdical Products, Inc. 3535 Kings Mills Road Mason, Ohio 45040-2303 USA Authorized European Community Representative 1-800-735-0357(Customer Service) HAAG-STREIT UK 1-800-735-0358 (Technical Service) (513) 398-3937 Edinburgh Way Http://www.reliance-medical.com Harlow, Essex, England CM20 2TT P/N 27158 REV E United Kingdom ©...