Troubleshooting - Water Soft ISOBAR II Installation & Operation Manual

Filter manual
Hide thumbs Also See for ISOBAR II:
Table of Contents

Advertisement

Troubleshooting Guide
F.
To Replace Meter
1. Follow steps A1 - A3
2. Unplug meter cable from front of circuit board.
3. Unscrew meter assembly nut from valve body.
4. Remove meter from valve body and clean or replace as necessary.
5. Reinstall meter, nut and cable.
SYMPTOM
1. Filter Fails to
Regenerate
Automatically
2. Regeneration at
Wrong Time
4. Poor Water Quality
6. Loss of Water Pressure
7. Continuous Flow to
Drain
PROBABLE CAUSE
Power supply plugged into
intermittentent or dead power source
Improper control valve
programming
Defective power supply
Defective Drive motor
Time of day improperly set, due to
power failure
Regeneration time set improperly
Check items listed in #1 and #2
Bypass valve open
Channeling
Scaling / fouling of inlet pipe
Fouled media
Improper backwash setting
Foreign material in control
Internal control leak
Valve jammed in backwash, brine or
rapid rinse position
Motor stopped or jammed
CORRECTION
Connect to constant power source
Reset program settings
Replace power supply
Replace motor
Reset time of day programming and
install 9-volt battery.
Reset regeneration time programming
Close bypass valve.
Check for too slow or high service
flow. Check for media fouling.
Clean or replace pipeline. Pretreat to
prevent.
Clean media. Pretreat to prevent.
Backwash more frequently
Call dealer. Clean valve and replace
piston and seals
Same as above.
Same as above.
Check for jammed piston. Replace
piston and seals. Replace motor if
motor is unresponsive.
21