Inspect
Doors, Surrounds
and Fronts
Gasket Seal, Glass
Assembly and Glass
Valve Compartment
and Firebox Top
Logs
Firebox
Burner Ignition and
Operation
Remote controls
26
1. Assess condition of screen and replace as necessary.
if one is not present.
2. Inspect for scratches, dents or other damage and repair as necessary.
3. Verify no obstructions to airflow through the louvers.
4. Verify maintenance of proper clearance to combustible household objects.
1. Inspect gasket seal and its condition.
2. Inspect glass panels for scratches and nicks that can lead to breakage when exposed to
heat.
3. Confirm there is no damage to glass or glass frame. Replace as necessary.
4. Verify that latches engage properly, clip studs are not stripped, and glass attachment
components are intact and operating properly. Replace as necessary.
5. Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot
be removed.
1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these
areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.
2. Remove any foreign objects.
3. Verify unobstructed air circulation.
1. Inspect for broken, damaged, or missing logs. Replace as necessary.
2. Verify correct log placement and no flame impingement causing sooting. Correct as
necessary.
1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as
necessary.
2. Replace appliance if firebox has been perforated.
1. Verify burner is properly secured and aligned with pilot or igniter.
2. Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if
necessary.
3. Replace ember materials with new dime-size and shape pieces. Do not block ports or
obstruct lighting paths.
4. Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.
5. Inspect for lifting or other flame problems.
6. Verify air shutter is clear of dust and debris.
7. Inspect orifice for soot, dirt or corrosion.
8. Verify manifold and inlet pressures. Adjust regulator as required.
9. Inspect pilot flame strength. Clean or replace orifice as necessary.
10. Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration.
Clean with emery cloth or replace as required.
11. Verify millivolt output. Replace as necessary.
1. Verify operation of remote.
2. Replace batteries in remote transmitters and battery-powered receivers.
3. Verify batteries have been removed from battery back-up IPI systems to prevent premature
battery failure or leaking.
Heat-N-Glo LifeStyle Collection • Dakota 42, Dakota 42H • 4036-905 Rev. F • 11/04