Advertisement

Models:
7000TV
6000TVB
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
GUIDE
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
Please contact your Heat-N-Glo dealer for any
questions or concerns. For the number of your
nearest Heat-N-Glo dealer, please call 952-985-6000.
Printed in U.S.A. Copyright 2000,
Heat-N-Glo, a division of Hearth Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
1
Installers Guide
Underwriters
Laboratories Listed
INSTALLERS

Advertisement

Table of Contents
loading

Summary of Contents for Heat-N-Glo 7000TV

  • Page 1 ASSISTANCE OR ADDITIONAL INFOR- MATION CONSULT A QUALIFIED IN- STALLER, SERVICE AGENCY, OR THE GAS SUPPLIER. Please contact your Heat-N-Glo dealer for any questions or concerns. For the number of your nearest Heat-N-Glo dealer, please call 952-985-6000. Printed in U.S.A. Copyright 2000, Heat-N-Glo, a division of Hearth Technologies Inc.
  • Page 2: Safety And Warning Information

    SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED.
  • Page 3: Table Of Contents

    Appliance Certification..............8 Installation Codes ................8 High Altitude Installations ............... 8 Section 2: Getting Started ............9 Introducing the Heat-N-Glo Gas Fireplaces ........9 Pre-installation Preparation ............9 Section 3: Installing the Fireplace........... 11 Step 1 Locating the Fireplace ..........11 Step 2 Framing the Fireplace...........
  • Page 4: Section 1: Approvals And Codes

    Approvals and Codes Appliance Certification Installers Guide Certification High Altitude Installations Installation Codes Heat-N-Glo Quality Systems registered by SGS ICS...
  • Page 5: Section 2: Getting Started

    Getting Started Introducing the Heat-N-Glo Gas Fireplaces Installers Guide Pre-install Preparation Installers Guide...
  • Page 6 VENT COLLARS STANDOFFS HOOD BOTTOM GRILLE COVER RATING PLATES & LABELS OUTSIDE CONTROLS ELECTRICAL GAS ACCESS ACCESS...
  • Page 7: Section 3: Installing The Fireplace

    Installing the Fireplace Step 1. Locating the Fireplace Step 2. Framing the Fireplace CAUTION: MEASURE FIREPLACE DIMENSIONS AND VERIFY FRAMING METHODS AND WALL COVERING DETAILS BEFORE FRAMING. Framing should be constructed of 2 X 4 lumber or heavier. 42” 22” 36”...
  • Page 8: Step 3 Negative Pressure Make-Up Air

    Step 3. Negative Pressure Make-up Air Air Damper...
  • Page 9: Step 4 Installing The Vent System

    Step 4. Installing the Vent System LISTED LISTED TERMINATION CAP TERMINATION CAP A. Vent System Approvals LISTED SINGLE-WALL LISTED SINGLE-WALL GAS VENT GAS VENT NON-COMBUSTIBLE NON-COMBUSTIBLE CONSTRUCTION CONSTRUCTION B-TYPE B-TYPE VENT VENT MINIMUM VERTICAL RISE = 9FT MAXIMUM HORIZONTAL RUN = 15FT V:H = 2:1...
  • Page 10: Bedroom Installation In Canada

    Step 5. Positioning, Leveling, and Securing the Fireplace WARNING: To ensure proper clearances the front framing header must be installed on its narrow edge and to the front of the frame. LOWEST DISCHARGE OPENING TERMINATION ROOF PITCH IS X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Step 6.
  • Page 11: Step 7 The Gas Supply Line

    SHUT-OFF VALVE IGNITOR GAS VALVE 7000TV FLEX CONNECTOR 1/4” (6.4mm) Step 8. Gas Pressure Requirements Pressure requirements for Heat-N-Glo gas fireplaces Step 7. The Gas Supply Line are shown in the table below. Pressure Natural Gas Propane Minimum 5.0 inches 11.0 inches...
  • Page 12: Step 9 Wiring The Fireplace

    Step 9. Wiring the Fireplace CAUTION: DISCONNECT REMOTE CONTROLS IF AB- SENT FOR EXTENDED TIME PERIODS. THIS WILL PRE- VENT ACCIDENTAL FIREPLACE OPERATION. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
  • Page 13 CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- TION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA- TION. VERIFY PROPER OPERATION AFTER SERVICING.
  • Page 14: Step 10 Finishing

    Step 10. Finishing Step 11. Installing Trim, Logs, and Ember Material CEILING 12" 31” 12” TOP FRONT EDGE OF FIREPLACE CAUTION: IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 300° F. MINIMUM SEALANT MATE- RIAL MUST BE USED.
  • Page 15: Step 12 Before Lighting The Fireplace

    Step 12. Before Lighting the Fireplace Installers Guide Step 13. Lighting the Fireplace CAUTION: IT IS STRONGLY RECOMMENDED THAT TRIM DOORS WITH OPTIONAL MESH SCREENS BE IN- STALLED ON PROPANE MODELS. After the Installation...
  • Page 16: Section 4: Maintaining And Servicing Your Fireplace

    Maintaining and Servicing Your Fireplace Fireplace Maintenance 7000TV 6000TVB MAKE SURE THE FLAMES ARE STEADY—NOT LIFTING OR FLOATING.