1. NO POWER

If the unit doesn't work by no power problem, repair the set according to the following guide.
1-1. FUSE & BRIDGE DIODE
1-1-1. Solution
Please check and replace F901, BD901, TH901 or TH903 on SMPS board.
1-1-2. How to troubleshoot (Countermeasure)
1) Check if the fuse F901 is open or short-circuit.
2) Check if the bridge diode BD901 is short-circuit by over current with a digital multi meter.
3) Check if the NTC thermistor TH901 or TH903 is normal or open.
1-1-3. Service hint (Any picture / Remark)
< F901 >
If F901 is not short-circuit,
replace it with a same specifi ca-
tions one.

ONE POINT REPAIR GUIDE

< BD901 >
If BD901 is short-circuit,
replace it with a new one.
3-2
< TH901 >
If TH901 is open,
replace it with a new one.