Common Section
Item
Condition
1. Setting
1) BATT terminal voltage: 7.5V
2) SSG standard modulation
[Wide]
MOD: 1kHz, DEV: 3kHz
[Narrow]
MOD: 1kHz, DEV: 1.5kHz
2. Receive
1) TEST CH: 3
VCO Lock
Voltage
2) TEST CH: 2
3. Transmit
1) TEST CH: 3
VCO Lock
Press [Transmit] button.
Voltage
2) TEST CH: 2
Press [Transmit] button.
Transmitter Section
Item
Condition
1. Frequency
1) TEST CH: 3
Press [Transmit] button.
2. High
1) Adj item: Low, Low', Center,
Transmit
High', High (5 points)
Power
BATT terminal voltage: 7.5V
Press [Transmit] button.
3. Low
1) Adj item: Low, Low', Center,
Transmit
High', High (5 points)
Power
BATT terminal voltage: 7.5V
Press [Transmit] button.
4. DQT
1) Adj item: Low, Center, High
Balance
(3 points)
[Narrow]
Deviation meter fi lter
LPF: 3kHz
HPF: OFF
Press [Transmit] button.
5. Maximum
1) Adj item: Center, Low, High
Deviation
(3 points)
[Narrow]
AG: 1kHz/150mV
Deviation meter fi lter
LPF: 15kHz
HPF: OFF
Press [Transmit] button.
[Wide]
2) TEST CH: 1
Press [Transmit] button.
36
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power
TX-RX
ANT
meter
(A/3)
DVM
CV
Measurement
Test-
Unit
Terminal
Unit
equipment
f. counter TX-RX
ANT
(A/3)
Power
meter
Ammeter
Power
TX-RX
ANT
meter
(A/3)
Deviation
SP/MIC
meter
connector
Oscilloscope
AG
AF VTVM
Adjustment
Parts
Method
FPU
4.4V
±0.1V
Check
0.6V or more
4.2V
±0.1V
Check
0.6V or more
Adjustment
Parts
Method
FPU
469.900MHz
±50Hz
FPU
4.8W
±0.1W
1.9A or less
1.0W
±0.1W
0.9A or less
FPU
Adjust 2kHz
±0.5dB
deviation to be the
same as 20Hz.
2.1kHz
±100Hz
(According to
the lager +, –)
4.2kHz
±100Hz
(According to
the lager +, –)
Specifi cations / Remarks
Specifi cations / Remarks