System Diagram ........................2 Hardware ..........................2 Powering the Hardware ......................3 Wiring Harness ......................... 5 Introduction The National Instruments 9755 CompactRIO NOx Sensor Module Kit interfaces with NO exhaust gas sensors. Features • Configurable from one to four channels •...
• NI-9853 CompactRIO High-Speed CAN module The wiring harness in the NI 9755 connects to the NOx Sensor Control Module and splits into two cables for the NI-9853 module and an external power supply. The first cable connects to the NI-9853 with a female DB-9 connector.
Powering the Hardware The NI 9755 requires power from a range of 12 V to 16 V with a continuous current of 1.5 A and a peak current of 16 A. The maximum power requirement is 20 W, which typically occurs when the heating element is being turned on from a cold state.
Page 4
Thread Torque...........50 N · m (36.88 lb · ft) Lubrication............Anti-seize compound Figure 2. Installation Position 0° +80° –80° Exhaust Gas Pipe Figure 3. Tilt Angle in Gas Flow Direction 90° –10° +10° 4 | ni.com | NI 9755 User Manual...
Batt and GND wires manufactured in 2018 or earlier use 18 AWG wires. Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or...