Siemens Simatic Net Scalance M812 Operating Instructions Manual page 12

Industrial remote communication remote networks
Hide thumbs Also See for Simatic Net Scalance M812:
Table of Contents

Advertisement

Security recommendations
The table includes the following columns:
● Protocol
All protocols that the device supports
● Port number
Port number assigned to the protocol
● Port status
– Open
– Open (when configured)
● Factory setting
– Open
– Closed
● Authentication
Specifies whether or not the protocol is authenticated during access.
With some protocols the port can be open but access is prevented by a predefined IP
package filter rule. You will find further information on the predefined IP package rules in
"Security > Firewall > Predefined IPv4"
Protocol
SSH
HTTP
HTTPS
SNTP
SNMP
DNS
Syslog
IPsec
DHCP
NTP
Siemens Remote Service
(cRSP/SRS)
PROFINET
12
The port is always open and cannot be closed.
The port is open if it has been configured.
The factory setting of the port is "Open".
The factory setting of the port is "Closed".
Port number
Port status
TCP/22
Open (when configured)
TCP/80
Open (when configured)
TCP/443
Open
UDP/123
Open (only outgoing)
UDP/161
Open (when configured)
TCP/53
Open (when configured)
UDP/53
Open (when configured)
UDP/514
Open (only outgoing)
UDP/500
Open (when configured)
UDP/4500
UDP/67
Open (when configured)
UDP/68
UDP/123
Open (only outgoing)
TCP/443
Open (only outgoing)
UDP/34964
Open (when configured)
Factory setting
Internal
External
interface
interface
Open
Closed
Open
Closed
Open
Closed
Closed
Closed
Open
Closed
Open
Closed
Open
Closed
Closed
Closed
Closed
Open
Open
Closed
Closed
Closed
Closed
Closed
Closed
Closed
Operating Instructions, 08/2016, C79000-G8976-C343-04
Authentication
Yes
Yes
Yes
No
Yes
No
No
No
Yes
No
Yes
Yes
No
SCALANCE M812, M816

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic net scalance m816Scalance m800