E231, Temperature Sensors - Samsung RC090MHXEA Service Manual

Eco heating system
Hide thumbs Also See for RC090MHXEA:
Table of Contents

Advertisement

E231, Temperature Sensors

E231 is an error with the outdoor refrigerant coil sensor. It's
connected to the main PCB in connector at the top right of the
PCB called CN43 in a white and red plug; it's the 3
rd
and 4
th
wire from the bottom.
To read what this sensor is
measuring you can ask the unit
using the interrogation function on
the outdoor unit main PCB
At the bottom of the main PCB are
4 buttons, you need to press K4, 7
times.
The display will show 07 XX
The XX will be the temperature this sensor is measuring; this sensor measures the refrigerant
temperature at the bottom of the big blue coil on the back of the outdoor unit, it's clipped to
the coil, you need to remove the back cover to get to it. You will need to compare the coil
temperature with the reading, if they are different the sensor needs replacing.
NOTE:
If your unit is constantly freezing up and not defrosting measure this
sensor, if the coil is frozen it should read 7-XX showing a negative
temperature. If it shows a positive temperature the sensor is faulty.
www.freedomhp.co.uk
©G Hendra Nov 18
22

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc160mhxea