ELECTRONIC CUBER MODEL EC 45
ice making capacity
AIR COOLED MODELS
K g .
24
23
22
21
20
19
18
17
16
15
32
27
21
WATER TEMPERATURE
NOTE . With the unit in "built-in" conditions, the ice production is gradually reduced in respect to the
levels shown in the graf, up to a maximum of 10% at room temperatures higher than 32 ° C.
The daily ice-making capacity is directly related to the condenser air inlet temperature, water
temperature and age of the machine.
To keep your SCOTSMAN CUBER at peak performance levels, periodic maintenance checks must
be carried out as indicated on page 41 of this manual.
SPECIFICATIONS
°C
o
10
21
32
38
°C
o
15
10
°C
°F
Important operating requirements:
Air temperature
Water temperature
Water pressure
Electr. voltage variations
from voltage rating
specified
on nameplate
WATER COOLED MODELS
K g .
24
23
22
21
20
19
18
17
16
15
32
27
21
15
WATER TEMPERATURE
Page 3
MIN.
MAX.
10°C
40°C
5°C
40°C
1 bar
5 bar
-10%
+10%
°C
o
10
21
32
38
°C
o
10