TC-15DT2
10.5.4. NTSC picture video (S terminal)
Measuring instrument
Remote control transmitter
Video signal
Oscilloscope
• • • • Receive 100% color bar signal at video input 1 (S terminal).
• • • • Enter the adjustment mode and adjust the amplitude level of each signal in the following steps.
1. Y signal (TS7)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below YGAIN indication so that the
value below MAX indication becomes D4. When adjusted, measure the amplitude between pedestal and white peak.
2. B-Y signal (TS8)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below B-Y indication so that the
amplitude (yellow-blue) at TS8 becomes equal to the value measured in the YGAIN adjustment.
3. R-Y signal (TS9)
With [VOLUME+/-] buttons of the remote control transmitter, adjust the value appearing below R-Y indication so that the
amplitude (cyan-red) at TS9 becomes equal to the value measured in the YGAIN adjustment.
Connection
PICTURE ADJUST
TS7~TS10 (GND)
NORMAL
TS8~TS10 (GND)
TS9~TS10 (GND)
DYNAMIC
34
LCD AI
OFF
PIC MODE