MUTE
Allows the muting of the unit's RF path.
POWER DETECTION
This menu shows the current input and output power levels as well as allowing the user to set
the input power alarm level and compression alarm level.
An input fault is generated if the input power level is less than the input alarm level set off this
menu, this facility can be disabled via the "Disable I/P alarm menu option".
A compression fault is generated if the output power level is greater than the compression
alarm level set off this menu.
REMOTE CONTROL
Selects a sub-menu with further menus. If the Ethernet module is not installed then the
following menu will be shown:
1 Set REMOTE mode - Sets the unit to allow control from a remote source. Pressing 1 again
returns the unit to local mode.
2 SETUP RS485 - Allows the selection of RS485 UNIT ADDRESS and BAUD RATE.
3 SETUP RS232 - Allows selection of BAUD RATE for RS232 communication.