Advertisement

Quick Links

EOM
Engineering
Operation &
Maintenance
PS Stallion
Original
Metal Pump
Where Innovation Flows
wildenpump.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS Stallion Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilden PS Stallion Series

  • Page 1 Engineering Operation & Maintenance PS Stallion Original Metal Pump ™ Where Innovation Flows wildenpump.com...
  • Page 2: Table Of Contents

    ..........1 SECTION 2 WILDEN PUMP DESIGNATION SYSTEM ....... . .2 SECTION 3 HOW IT WORKS—PUMP &...
  • Page 3: Cautions-Read First

    fire or explosion could result. Pump, valves and containers must be grounded CAUTION: Tighten all hardware prior to installation. to a proper grounding point when handling flammable fluids and whenever discharge of static electricity is a hazard. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 4: Wilden Pump Designation System

    WF = WIL-FLEX™ [Santoprene ® (Orange Dot)] SPECIALTY CODES 0046 Stallion internals, BSPT 0048 Stallion Internals 0050 Stallion 0051 Stallion, BSPT 0076 Food Processing, Stallion Internals NOTE: Bold specialty codes indicate the standard product offering. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 5 H O W I T W O R K S — P U M P The Wilden diaphragm pump is an air-operated, positive displacement, self-priming pump. These drawings show flow pattern through the pump upon its initial stroke. It is assumed the pump has no fluid in it prior to its initial stroke.
  • Page 6: Dimensional Drawings

    LW0261 REV. B PS 8 S t a l l i on DIMENSIONS ITEM METRIC (mm) STANDARD (inch) 16.0 24.1 14.3 24.8 26.4 13.6 14.8 18.1 13.8 10.8 15 DIA. 0.6 DIA. LW0262 REV. C WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 7 D I M E N S I O N A L D R A W I N G S PS15 S t a l l i on DIMENSIONS ITEM METRIC (mm) STANDARD (inch) 19.5 29.2 16.6 30.3 32.6 16.3 16.7 19.6 16.1 12.0 15 DIA. 0.6 DIA. LW0263 REV. B WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 8: Ps4 - Ez-Install Tpe-Fitted

    Caution: Do not exceed 8.6 bar (125 psig) For optimum life and performance, pumps should be specified so that daily operation air supply pressure. parameters will fall in the center of the pump's performance curve. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 9: Ps15 - Ez-Install Tpe-Fitted

    Caution: Do not exceed 8.6 bar (125 psig) air supply pressure. For optimum life and performance, pumps should be specified so that daily operation parameters will fall in the center of the pump's performance curve. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 10: Suction-Lift Curves

    fluid, elevation (atmospheric pressure) and to be a guide only. There are many variables which pipe friction loss all affect the amount of suction lift can affect your pump’s operating characteristics. The your pump will attain. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 11 The number of intake and discharge elbows, viscosity of pumping fluid, elevation (atmospheric pressure) and pipe friction loss all affect the amount of suction lift your pump will attain. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 12 N O T E S...
  • Page 13 Wilden offers the widest variety of elastomer PIPING: Final determination of the pump site should not be options in the industry to satisfy temperature, chemical- made until the piping challenges of each possible location compatibility, abrasion-resistance and flex concerns.
  • Page 14 AIR OPERATED PUMPS: To stop the pump from operating in an emergency situation, simply close the in an emergency situation. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 15 fluid Pump discharge rate can be controlled by limiting all affect the parts life of a Wilden pump. Periodic the volume and/or pressure of the air supply to the inspections have been found to offer the best pump.
  • Page 16: Disassembly / Reassembly

    Inspect the ball cage area of the alignment. This will assist in proper handles (if equipped) and the two manifold for excessive wear or alignment during reassembly. small clamp bands that fasten the damage. discharge manifold to the liquid chambers. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 17 Replace worn appropriate-sized wrench, remove the air chamber and center section parts with genuine Wilden parts for the suction hook up cover from assembly. reliable performance. the inlet manifold. Inspect the...
  • Page 18 Step 13 To remove diaphragm assembly from shaft, secure shaft with soft jaws (aluminum, plastic, or plywood) to ensure the shaft is not damaged. Using an adjustable wrench, remove the diaphragm assembly from the shaft. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 19: Air Valve/Center Section Disassembly

    Using a pair of snap-ring pliers, Using an O-ring pick, remove O-ring Using the appropriate-sized wrench, remove the snap ring from pilot from modulator spool. loosen and remove the fasteners sleeve. that attach the air chamber to center section. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 20 first, this will damage the single urethane O-ring by passing it over the ports in the pilot sleeve. NOTE: Seals should not be removed from the assembly. Seals are not sold separately. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 21 Lift away the air valve assembly and four (4) air valve bolts from center remove air valve gasket. Inspect the gasket and replace if necessary. section assembly. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 22 (04-2638-52). The single-point air valve gasket can of the center block. Install 1/4" NPT be purchased as a spare part or included with the pipe plug (00-7010-08) into bleed purchase of a new Pro-Flo SHIFT pump. ® port. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 23: Reassembly Hints & Tips

    Inner Piston Ring 19 N•m (15 ft-lb) Outer Piston 108 N•m (80 ft-lb) Small Clamp Bands 15.5 N•m (137 in-lb) Large Clamp Bands 61 N•m (45 ft-lb) Figure A SHAFT SEAL SHAFT SEAL TAPE TAPE WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 24: Exploded View & Parts Listing

    PS4 STALLION E X P L O D E D V I E W FULL-STROKE TPE 20 5 METAL ADS LWO275 Rev. B ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS (see section 9). WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 25 (Screen), (4) 04-6140-08 (Bolt) Piston, Outer 04-4552-01 04-4550-08 and (4) 15-6740-08-50 (Washer). Screw, HHC, (1/2"-20 X 1-1/2") 04-6091-08 All boldface items are primary Washer (.513 X 2.188 X .194) 04-6800-08 wear parts. LW0276 Rev. D WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 26: Ps8 Stallion Metal

    E X P L O D E D V I E W & P A R T S L I S T I N G PS8 STALLION E X P L O D E D V I E W METAL ADS LWO277 Rev. B ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS (see section 9). WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 27 LW0278 Rev. C *Refer to Elastomer Chart - see Section 9. Metal Center Block Assembly includes items 11, 12 and 14. Air Valve Assembly includes items 2 and 3. All boldface items are primary wear parts. WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 28: Ps15 Stallion Metal

    E X P L O D E D V I E W & P A R T S L I S T I N G PS15 STALLION E X P L O D E D V I E W LWO279 Rev. B METAL ADS ALL CIRCLED PART IDENTIFIERS ARE INCLUDED IN REPAIR KITS (see section 9). WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 29 15-6740-08-50 Air Valve Assembly includes items 2 and 3. Diaphragm, Primary Metal Center Block Assembly includes items 11, 12 and 14. Piston, Outer 15-4550-01 All boldface items are primary wear parts. LW0280 Rev. C WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 30: Elastomer Options

    MATERIAL Polyurethane 15-1022-50 15-1080-50 Neoprene 08-1080-51 15-1120-51-50 Buna-N 08-1080-52 15-1120-52-50 ® Geolast 15-1022-15 ® EPDM 08-1080-54 15-1120-54-50 Viton 08-1080-53 15-1120-53-50 ® Saniflex™ 15-1022-56 15-1080-56 FDA Wil-Flex™ 15-1022-57 15-1080-57 Wil-Flex™ 15-1022-58 15-1080-58 LW0280 Rev. C WILDEN PUMP & ENGINEERING, LLC WIL-10830-E-02...
  • Page 31 Since the use of Wilden pumps and parts is beyond our control, we cannot guarantee the suitability of any pump or part for a particular application and Wilden Pump and Engineering, LLC shall not be liable for any consequential damage or expense arising from the use or misuse of its products on any application.
  • Page 32 Where Innovation Flows 22069 Van Buren Street, reserves the right to modify the information and illustrations contained in this document without prior notice. This is a non-contractual document. 04-2015 ® Grand Terrace, CA 92313-5607 Authorized PSG Representative: Telephone: (909) 422-1731 Fax: (909) 783-3440 22069 Van Buren St., Grand Terrace, CA 92313-5607 P: +1 (909) 422-1731...