Table of Contents

Advertisement

Centrella™ Smart+ Bed
Product Reference Guide
1
©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED.
205278 rev 2 13-SEP-2017 ENG – US

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Centrella Smart+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hill-Rom Centrella Smart+

  • Page 1 Centrella™ Smart+ Bed Product Reference Guide ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 2: Table Of Contents

    • Patient Siderail Controls & Head-of-bed Angle Indicator ......................15 • Patient Hip Position Indicator & Advanced SlideGuard® Feature .....................15 • USB Charging (Optional Feature) & Patient Device Storage ......................15 • Urinal Holder ........................................15 ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 3 – Surface Modes ......................................26 – Turn Assist........................................26 • Scale Operations ......................................27 – Zeroing the scale .......................................28 – Weighing the patient ....................................29 • Settings & Preferences ....................................30 ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 4: General Frame Overview

    1-800-445-3730 and a customer service representative will direct you to your local representative. Introduction At Hill-Rom, we understand that life-altering moments happen on a hospital bed. It’s where life begins. Where care is delivered. Where healing happens. All too often, costly complications can happen when life-altering health events occur. The Centrella™ Smart+ bed is purposefully designed to best address your primary concerns and meet the changing needs of healthcare facilities.
  • Page 5: Audible And Visual Alerts

    • White power cord: This cord powers the optional auxiliary accessory outlet located on the left side of the base frame, below the intermediate siderail. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 6: Battery Backup

    If the Nurse Call control is not visible, but the bed communication cable is connected, contact your authorized maintenance personnel. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 7: Line Managers

    WARNING: Restraints must be attached to the articulating section of the bed at the correct attachment points. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 8: Foley/Drainage Bag Holders & Foley Position Limit

    Siderail Lights Foley Limit Set Foley Position Limit Reduces the likelihood of drainage bags touching the ground by limiting foot down and Reverse Trendelenburg. Accept Cancel ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 9: Safeview®+ System (Optional Feature)

    Alert for 1 Rail Restraint back to your facility’s default settings. Accept • Some rail combination settings may be unsafe for some patients. Follow your facility’s protocol. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 10: Bed Exit Alert Status

    NOTE: The IllumiGuide™ handgrip stays illuminated for 15-minutes after the patient is out of bed. When the patient gets back into bed, it will automatically turn off after 2-minutes. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 11: Motion Activated Nightlight

    • Use correct lifting techniques and ask for assistance when installing or removing the Patient Helper. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 12: Point-Of-Care® Caregiver Controls

    To level the legs and foot, press and hold Knee Down until the bed stops and you hear a single beep. The knees and feet will be level. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 13: Boost® Positioning System

    • Use the patient hip position indicator on the intermediate siderail to align the patient’s hips in correct position to optimize performance of the Advanced SlideGuard® feature. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 14: Trendelenburg& Reverse Trendelenburg

    This will lockout both patient and caregiver controls. NOTES: • To unlock, repeat the same steps. • When CPR is activated, any controls that are locked out will become unlocked. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 15: Patient-Focused Features

    This can result in strangulation. Secure any excess cable to the siderail or another suitable object. Urinal Holder The integrated urinal holder provides a dedicated place to hang a urinal, providing easy access for the patient. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 16: Patient Pendant

    After 15-minutes, the feature times out and the surface will return to the Normal setting. NOTE: Train ambulatory patients to use this before getting out of bed. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 17: Patient Comfort Controls (Optional Feature)

    • Green indicator: communication line with nurse’s station is open NOTE: Nurse Call controls can never be turned off. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 18: Transport

    For beds without IntelliDrive® Powered Transport, continue to transport the patient per your facility’s protocol. For beds with IntelliDrive® Powered Transport, refer to the “Transporting with IntelliDrive® Powered Transport” section. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 19: Transporting With Intellidrive® Powered Transport (Optional Feature)

    Corner Bumper with Equipment Sockets Located at each corner of the bed, there are four equipment sockets for attaching accessories such as IV poles and oxygen tank holders. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 20: Gci® Touchscreen

    At any time, you can press the Home control to return to the Home screen. Head Angle 32˚ <30˚ Limit Stand Assist ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 21: 30° Head-Of-Bed Limit

    • In the lowest chair position, make sure the drainage bags do not touch the floor and move them if necessary. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 22: Stand Assist Control

    (76” inner, 87” outer) and fully extended position (88” inner, 99” outer). • The FlexAfoot™ feature is available on battery backup and can be used during transport to adjust to small spaces such as an elevator. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 23: Bed Exit Alert System

    Bed Exit Off. The Alert Status Indicator changes to an “X, ” the icon is no longer green. “Exit Alert Off” message will appear on the touchscreen for 10-seconds. Resume Bed Exit Off ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 24: Respond And Silence

    The bed will remain in this state until the patient returns to the bed or the Bed Exit alert is turned Off. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 25 If the bed is unplugged for transport when the Bed Exit is armed, the alert will automatically re-arm when plugged back into power. It does NOT work on battery backup. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 26: Centrella™ Max Surface Controls (Optional Feature)

    • For proper operation, there must be a minimum of 32 kgs (70 lbs) on the Normal Max Inflate surface. Right Turn Comfort • Use loose, fitted sheets, preferably knitted, for maximum pressure Left Turn redistribution. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 27: Scale Operations

    • The scale is very sensitive. Make sure the bed is not touching anything that could affect the patient weight, such as a wall or furniture. Failure to do so could cause an inaccurate reading. ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 28: Zeroing The Scale

    • Bed will not zero if it detects >45 kilograms to prevent zeroing the scale Cannot Zero! with the patient in the bed. Remove Patient or excess weight from bed and zero. Help ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 29: Weighing The Patient

    • The patient is not centered in the bed. This icon will indicate • The patient is causing excessive bed movement. weight taken out of position. Cancel ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...
  • Page 30: Settings & Preferences

    Screen Brightness of the GCI Touchscreen can be adjusted to accommodate “Care-Team called.” patient light-sensitivities at night. “Function unavailable.” “Call Light not connected” Accept Screen Brightness Accept ©2017 Hill-Rom Services, Inc. ALL RIGHTS RESERVED. 205278 rev 2 13-SEP-2017 ENG – US...

Table of Contents

Save PDF