® REBOTEC Rehabilitationsmittel GmbH PO Box Q541 Queen Victoria Building NSW 1230 BA No.: 02.07.147/2017-01 rebotec.com.au info@rebotec.com.au User Instructions Electric Tilt & Lift Shower Chair Phoenix Multi Phoenix Multi Seat with hygiene opening Enclosed seat 352.xx.10 352.xx.40 Serial Number Serial Number...
REBOTEC / BA No.: 02.07.147/2017-01 Product description Table of contents General advisories Introduction Note LINAK mounting instructions Intended proper use Symbols used Use and storage Equipment Warranty Nameplate, ordering spare parts Re-use, product lifetime Disposal Safety advisories for use Product specifications...
REBOTEC / BA No.: 02.07.147/2017-01 Packaging 1.4 Symbols used Keep packaging later transport. This will allow proper Read the Year of packaging in the event of a return instructions! Manufacture shipment. Product complies to the Medical 1. General advisories Products Directive 93/42/EEC 1.1 Introduction...
Further information can also be obtained from the The delivery date written on the REBOTEC- assembly instructions of LINAK. See point 1.2 delivery note applies as the valid start date of the warranty period.
REBOTEC / BA No.: 02.07.147/2017-01 armrests up or down. See section 11.8, page 12 properly operated or used. Therefore keep hands for more information. and feet away from these parts, and do not reach To prevent body parts or objects from getting into the lifting unit during raising and lowering the chair.
REBOTEC / BA No.: 02.07.147/2017-01 9.3 Installing, adjusting the headrest Caution! Installation: All cables must be routed in such a way, preventing Flip the levers (A) upwards people from stumbling, and causing injury during and insert the tubes of the use.
REBOTEC / BA No.: 02.07.147/2017-01 down laying position Maintenance advisories If the function of the locking lever becomes difficult or too easy, then 9.7 Installing/removing the safety belt the clamping effect can The safety belt is already installed when the chair is regulated delivered.
Ensure that no cables lying in the wall are damaged Display during assembly. REBOTEC shall not be liable for any damage resulting from the attachment of the LED 1 “ON“- not illuminated: charger. Make sure that the length of the main cable The mains cable is not plugged into the (approx.
REBOTEC / BA No.: 02.07.147/2017-01 The external charger has a power of 1.3 watts 10.4 EMERGENCY STOP function in idle mode (without charging a battery). To save power, unplug the power cord after each Pressing the red EMERGENCY STOP button locks charging operation.
REBOTEC / BA No.: 02.07.147/2017-01 Display both armrests must be securely latched in position. Also the seat must be properly in place and the foot LED-off: plates must be moved to the side or folded up. Battery capacity sufficient. LED-orange: If the LED "orange"...
REBOTEC / BA No.: 02.07.147/2017-01 11.3 Sitting and laying / low position The wheel and castor are released by pressing the lever upwards with your foot (2). 11.6 Removing the seat pad The seat with (I) and without (O) hygiene opening,...
REBOTEC / BA No.: 02.07.147/2017-01 11.9 Removing the footrests 12. Troubleshooting Lift the footrests approx. 100mm (3.94”) and rotate Chair malfunctions/faults them outward 90°. Now you are able to push the footrests all the way up and to pull them out.
REBOTEC / BA No.: 02.07.147/2017-01 In the event of any inadequacies, do not put the Do not use an abrasive scouring agent or cleaner (read the product instructions!) that contain product to use and do not carry out any repairs aggressive solvents (acids, benzene, thinners, on your own.
Page 15
REBOTEC / BA No.: 02.07.147/2017-01 - 15 -...