To avoid AF error from continuous 24 hour AF
mode usage, daily initialization of lens system
using the CAM_Initialize command is
recommended.
The CAM_Initialize command takes less than 3
seconds to initialize the focus and zoom.
• Manual Focus Mode
MF (Manual Focus) has both a Standard Speed Mode
and a Variable Speed Mode. Standard Speed Mode
focuses at a fixed rate of speed. Variable Speed Mode
has eight speed levels that can be set using a VISCA
Command.
Will not stop by this command itself in Standard
Speed Mode and Variable Speed Mode. To stop, a
Stop command must be sent.
• One Push Trigger Mode
When a Trigger Command is received, the lens
moves to adjust the focus for the subject. The focus
lens then holds the same position until the next
Trigger Command is input.
• Infinity Mode
The lens is forcibly moved to a position suitable for
an unlimited distance.
• Near Limit Mode
Can be set in a range from 1000 ( ) to C000 (10 mm).
The focus range is narrowed by excluding the
unnecessary range.

White Balance

White Balance has the following modes, all of which
can be set using VISCA Commands.
• Auto White Balance
This mode computes the white balance value output
using color information from the entire screen. It
outputs the proper value using the color temperature
radiating from a black subject based on a range of
values from 3000 to 7500K.
This mode is the default setting.
• ATW
Auto Tracing White balance (2000 to 10000 K)
• Indoor
3200 K Base Mode
• Outdoor
5800 K Base Mode
.................................................................................................................................................................................................................................
1) Flicker can be eliminated by setting shutter to:
t
1
/
s for NTSC models used in countries with a 50 Hz power supply
100
frequency.
• One Push WB
The One Push White Balance mode is a fixed white
balance mode that may be automatically readjusted
only at the request of the user (One Push Trigger),
assuming that a white subject, in correct lighting
conditions and occupying more than
is submitted to the camera.
One Push White Balance data is lost when the power
is turned off. If the power is turned off, reset the One
Push White Balance.
• Manual WB
Manual control of R and B gain, 256 steps each
Automatic Exposure Mode
The variety of AE functions, which allow video signal
to output the optimum image for subjects from low
light conditions to bright light conditions, are
available.
• Full Auto
Auto Iris and Gain, Fixed Shutter Speed (NTSC:
1
s, PAL:
/
s)
50
• Shutter Priority
1)
Variable Shutter Speed, Auto Iris and Gain
(
1
/
to
1
/
s, 22 steps, std. shutter: 16 steps, slow
1
10,000
shutter: 6 steps)
• Iris Priority
Variable Iris (F1.4 to Close, 18 steps), Auto Gain and
Shutter speed.
• Manual
Variable Shutter, Iris and Gain.
• Bright
Variable Iris and Gain (Close to F1.6, 17 steps at
0 dB: F1.4, 15 steps from 0 to 28 dB)
t
1
/
s for PAL models used in countries with a 60 Hz power supply
120
frequency.