Clarkson Slurry Knife Gate ValVeS
KGA+
reassembly
1. if valve has been removed from pipe, lift
valve to vertical position, refer to lifting,
Section 15.
2. using DOW iii or approved alternate,
completely fill all internal cavities of the
new secondary seal.
3. insert the new lubricated secondary seal
into the valve housing assembly. Make sure
that the lube path openings on the seal line
up with corresponding external housing
lubrication fittings.
4. Place the secondary seal retainer plate
into position.
5. replace and hand tighten all the retainer
plate fasteners and lockwashers.
6. apply a small amount of recommended
lubricant to the two tapered faces of the
'sharp end' of the gate.
7. Press the gate firmly through the secondary
seal into the valve housing assembly until
the mark drawn on the gate reaches the
top of the retainer plate or gate reaches
dimension a, table 5, figure 13.
8. fully tighten all the retainer plate fasteners.
9. reinstall the actuator / frame assembly with
the housing / frame fasteners loosely.
10. reconnect the gate to the actuator. (in order
to facilitate installation and future removal,
a coating or anti-seize compound should be
applied to the outside of the clevis pin over
the yoke contact area).
table 4 - housinG i.d.
Valve size
i.d. minimum
nps
dn
inch
3
80
4.45
4
100
5.39
6
150
7.79
8
200
9.42
10
250
11.92
12
300
13.94
14
350
15.80
16
400
17.44
18
450
19.06
20
500
21.06
24
600
26.06
26
650
28.28
30
750
32.06
36
900
38.20
42
1050
45.06
48
1200
50.74
54
1350
55.74
60
1500
63.95
11. 'Stretch' the frame / actuator assembly
with respect to the housing by pulling (not
lifting) the frame / actuator assembly to
its maximum movement away from the
housing assembly (holding housing in place
if valve is removed from pipeline). tighten
the frame / housing bolts and verify the
tightness of the actuator to frame bolts.
12. Cycle valve to full open position and check
the gate position using the data in the
table 5, figure 13. adjust as required.
13. rattle the gate. it should be mostly
disengaged from the sleeves. the outboard
edges of the gate should be free and the
center still partially engaged in between
the sleeves.
14. Cycle gate full closed and full open.
15. inspect gate for pieces of rubber. if
significant amount of rubber is present, a
sharp edge(s) on the gate may be causing
seal damage or the gate is extending too
far on the up stroke. the ends of the gate
should be free and the center still engaged.
if the sleeve / gate is misaligned, loosen the
frame actuator bolts and / or adjust the yoke
until the proper position, open and closed,
is obtained.
16. if out of pipeline, reinstall the valve, refer
to lifting, Section 15.
i.d. maximum
mm
inch
mm
113.03
4.49
114.05
136.91
5.43
137.92
197.87
7.83
198.88
239.27
9.46
240.28
302.77
11.96
303.78
354.08
13.97
354.84
401.32
15.83
402.08
442.98
17.47
443.74
484.12
19.10
485.14
534.92
21.10
535.94
661.92
26.10
662.94
718.31
28.36
720.34
814.32
32.12
815.85
970.28
38.30
972.82
1144.52
45.19
1147.83
1288.80
50.77
1289.56
1415.80
55.77
1416.56
1624.33
63.99
1625.35
fiGure 11
seal retainer
Maximum allowable
housing i.d.
inch
mm
4.55
115.57
5.49
139.45
7.89
200.41
9.52
241.81
12.02
305.31
14.00
355.60
15.86
402.84
17.50
444.50
19.19
487.43
21.19
538.23
26.19
665.23
28.45
722.63
32.21
818.13
38.39
975.11
45.31
1150.87
50.89
1292.61
55.89
1419.61
64.11
1628.39
Secondary
Secondary
seal
11