Download Print this page

Cisco UCS B250 M1 Installation And Service Note page 15

Extended memory blade server

Advertisement

S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
Tighten the captive screw on the front of the blade to no more than 3 in-lbs. Tightening with bare fingers
Step 6
only is unlikely to lead to stripped or damaged captive screws.
Step 7
Power on the server. UCS Manager will automatically re acknowledge, reassociate, and recommission
the server, provided any hardware changes are allowed by the service profile.
Removing an Extended Memory Blade Server Cover
To open an extended memory blade server, follow these steps:
Press and hold the button down as shown in
Step 1
While holding the back end of the cover, pull the cover up and back.
Step 2
Figure 6
Installing and Removing the B250 M2 Air Baffle
The air baffle available with the M2 servers may need to be installed in M1 servers. You will need a #1
Phillips Screw Driver and a 1/4" Nut Driver to install the baffle. To install the baffle:
Step 1
Remove the top cover from the enclosure of UCS B250 Blade Server.
Using the screwdriver, remove the pan head screws securing the motherboard to the tray where the
Step 2
standoffs are shown in
Step 3
Using the nut driver, replace the pan head screws with the standoffs that are provided through the field
upgrade kit (N20-BBFLB=).
Note
If a Cisco UCS B250 M1 server with a single processor is installed in a chassis next to a Cisco UCS
B440 or B230 server, the Cisco UCS B440 or B230 may throttle down due to insufficient available
cooling. To avoid this, you will need to order or place an RMA for the Cisco UCS B250 M1 internal air
baffle N20-BBFLB=. This baffle is only required when co-installed Cisco UCS B250 M1 servers are
OL-22474-03
Opening an Extended Memory Blade Server
Figure
7.
Cisco UCS B250 Extended Memory Blade Server Installation and Service Note
Removing an Extended Memory Blade Server Cover
Figure 6
15

Advertisement

loading

This manual is also suitable for:

Ucs b250 m2