Installation Instructions Kemlan Power Flue Horizon Gas Fireplaces

Before Installation

The Power flue system shall be installed by authorized
personnel in accordance with the manufacturer's
installation instructions, local gas fitting regulations,
municipal building codes, electrical wiring regulations,
and any other statutory regulations. Contact your local
building authorities about restrictions and installation
inspections that may be required. If in doubt contact
your local dealer or Kemlan's Head office.
IMPORTANT AUSTRALIAN CODES:
Australian Standards AS 5601 Gas Installation
Australian Standards AS 3000 Electrical

Important Safety Notes

• Comply with all instructions in manual
including clearances to combustible material.
• Do not operate without fully assembling
all components.
• All open gas fires require ventilation in the
room.
• Do not connect to any other air distribution duct or
system.
• An A.G.A approved cowl is required at flue terminal.
• Refer to the table below for flue diameter and flue
cowl size.
• Air movement of systems- A decorative gas log fire
must not be installed where the operation of any
ventilation system, fan or air blower could in any
circumstances cause the air pressure to be less than
atmospheric at the appliance.
• Do not block or restrict chimney.
• After installing appliance check that the flue draws
well with smoke pellet.
• Kemlan recommends that all gas fires be serviced
every year.
• All gas units must be fitted by a licensed gas fitter.
• It is the responsibility of the gas fitter to follow the
regulations set out in the Gas Code that dictate the
procedures to follow when installing a gas appliance,
particularly regarding gas pipe sizing and checking of
pressures.
28/02/2019
Installation
1
The Power flue system is supplied with all
required electrical fittings. Work needs to be
undertaken by a licensed electrician if extending
wiring. Wiring requires clearance of minimum
100mm to flues and fireplace body due to heat. See
Wiring diagram page15. Wiring must be positively
secured away from heat source.
2
An isolation switch needs to be provided if
connecting within fireplace framework.
3 Build frame to specifications provided. Note: 80mm
clearance above fireplace and 5mm to front surface
of firebox.
4 Unit located on 10mm fiber cement sheeting.
Sheeting required for access to gas burner.
5 Unit and flues to be installed prior to plastering.
6
Gas line run to desired position prior to plastering.
7
Clearance of 25mm to vertical flue.
8
Allow for a minimum flue height of 3.6m.
9 All flue components to be riveted together.
10 Rooms with Gas Open Fires require fresh air vents,
refer to page 2 , Ventilation Requirements, for each
Decorative Gas and Coal Fire.
11 Important: Both caps to stay off if heat zone is not
used.
12 Important: if a heat zone kit with fan is used, the
unused outlet must remain uncapped.
13 Vent (240mm x 90mm) supplied by Kemlan is
required to ventilate chase to room
Rear clearances to
combustible material
Cantilever : 0mm
Low line: 25mm
Ver. 25