Horizon Fitness CANTLEVER 700 Installation Instructions Manual page 31

Power flue gas fireplaces
Table of Contents

Advertisement

Installation Instructions Kemlan Power Flue Horizon Gas Fireplaces
TAIS Flash Codes
LED Flash Code Descriptions
Flash Code (Long
flashes– short
flashes)
0-2
1-0
1-1
1-2
1-3
1-4
1-5
2-1
2-2
2-3
2-4
2-5
2-6
2-7
3-1
3-2
3-3
3-4
28/02/2019
Normal Start Up Operation
Normal Running State
Flame failure
Waiting for pressure switch ON
Waiting for pressure switch to go OFF
Waiting for flame sense to go OFF
Post Purge in progress
Maximum retries exceeded
Lockout due to flame failure
Hardware failure on Combustion fan drive, or microcontrollers disagree
Hardware failure on GAS1 valve drive, or microcontrollers disagree
Hardware failure on GAS2 valve drive, or microcontrollers disagree
Hardware failure on flame sensor
Relay Enable signal hardware failure (stuck in ON state)
Lockout due to pressure switch opening
Lockout due to EE memory corruption
Lockout due to inter-microcontroller communications link problem
Lockout due to comms error timeout
Description
Ver. 25