Power Over Ethernet - Dell Networking X1000 Series Getting Started Manual

Hide thumbs Also See for Networking X1000 Series:
Table of Contents

Advertisement

Available languages

Available languages

Rebooting the Switch in Managed Mode
To reboot the switch, press the Reset button through the pinhole on the
switch for less than seven seconds.
Resetting the Switch in Managed Mode
To reset the switch to factory defaults, press the Reset button through the
pinhole on the switch for more than seven seconds.
CAUTION:
When you reset the switch, any configuration information that has
been previously entered is lost.

Power Over Ethernet

The table below describes the PoE resources available for the various switch
models.
Table 1-2. Power Over Ethernet
PoE Switch Model
X1008
X1018p
X1026p
X1052p
*These ports can be PoE or PoE+
Watts (dedicated POE
power only)
123
246
369
369
Powered Ports
1-8
1-16
1-24*
1-24*
Getting Started Guide
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents