TH-37PV7F / TH-37PV7P / TH-37PX7B / TH-37PX7E / TH-42PV7F / TH-42PV7P / TH-42PX7B / TH-42PX7E
12 Adjustment
12.1. Sub-Contrast adjustment
Name of measuring instrument
RF generator
Base Band generator
1. Receive AV1 (PAL 100% Full White or Split Colour bar shown as below) .
2. Goes into service mode.
3. Push "1" or "2" key, and goes into service mode for "Sub-Contrast".
1. The colour key yellow button of remote control is pushed.
2. The OSD character of sub-contrast becomes red.
(Inside under automatic adjustment)
3. The OSD character of sub-contrast returns to black.
4. End.
1. Receive RF (PAL 100% Full White or Split Colour bar shown as below.)
2. Goes into service mode.
3. Push "1" or "2" key, and goes into service mode for "Sub-Contrast".
1. The colour key yellow button of remote control is pushed.
2. The OSD character of sub-contrast becomes red.
(Inside under automatic adjustment)
3. The OSD character of sub-contrast returns to black.
4. End.
1. Receive Component
(1080i/ 60Hz or 1080i/ 50Hz, 100% Full White or Split colour bar as shown below.)
2. Goes into service mode.
3. Push "1" or "2" key, and goes into service mode for "Sub-Contrast".
1. The colour key yellow button of remote control is pushed.
2. The OSD character of sub-contrast becomes red.
(Inside under automatic adjustment)
3. The OSD character of sub-contrast returns to black.
4. End.
Preparation (AV)
Adjustment of AV system
Preparation (RF)
Adjustment of RF system
Preparation (HD)
Adjustment of HD system
Connection
30
Remarks
Remarks
Remarks
Remarks
Remarks
Remarks
Remarks