TH-42PV500E / TH-42PV500B / TH-37PV500E / TH-37PV500B
2. Remove the screws (×3
connector L, R.
3. Remove the Speaker L, R.
6.24. Remove the stand brackets.
1. Remove the plasma panel section from the servicing stand
and lay on a flat surface such as a table (covered), with the
plasma panel surface facing downward.
Spread a soft cloth or similar on the table for protection, so
the panel surface is not scratched.
2. Remove the stand bracket (left, right) fastening screws (×4
each) and remove the stand brackets (left, right).
) and disconnect the relay
6.25. Remove the C3-Board
1. Remove the flexible cable holder fastening screws (×8), and
disconnect the flexible cables (CB5, CB6, CB7, CB8).
2. Disconnect the couplers (C33, C42, C44), and disconnect
the flexible cables (C31).
3. Remove the screws (×3
6.26. Remove the C4-Board
1. Remove the flexible cable holder fastening screws (×8
and disconnect the flexible cables (CB1, CB2, CB3).
2. Disconnect the coupler (C43) and disconnect the flexible
cables (C41).
3. Remove the screws (×3
18
), and remove the C3-Board.
), and remove the C4-Board.
)