NEC Express5800/A1040b User Manual page 36

Machine check monitoring service
Hide thumbs Also See for Express5800/A1040b:
Table of Contents

Advertisement

No.
Message
52
Cannot open /dev/mcelog. <error
cause>
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
53
MCE_GET_RECORD_LEN <error
cause>
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
54
MCE_GET_LOG_LEN <error
cause>
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
55
no data in mce record
mcemonitor found a continuable
error. mcemonitor will continue to
be run safely.
56
mcelog read <error cause>
mcemonitor found a continuable
error. mcemonitor will continue to
be run safely.
57
warning: xxxx bytes ignored in
each record
consider an update
mcemonitor can not analyze
mcelog due to the inconsistency of
log format. mcemonitor needs to
be updated.
58
Cannot open pidfile <error cause>
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
59
CPU 56
BANK 128
TSC 0x5e6974d4256
RIP 00:0
MISC 0
ADDR 0
STATUS 0x40000000883c0c00
MCGSTATUS 0
CPUID Vendor Intel Family 6
Model 62
TIME 1366542972 Sun Apr 21
20:16:12 2013
SOCKETID 0
APICID 23
MCGCAP 0x5000c20
60
error while recieving from kernel
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
61
cannot open NETLINK socket
<error cause>
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
Meaning
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
An error occurred on
system-related function, but
mcemonitor continue operation.
An error occurred on
system-related function, but
mcemonitor continue operation.
mce structure in Linux kernel
may be changed.
Update mcemonitor.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
MCE/CMC occurred.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
32
Action
Restart mcemonitor
automatically by cron.
Restart mcemonitor
automatically by cron.
Restart mcemonitor
automatically by cron.
mcemonitor continues
running. No action is needed.
mcemonitor continues
running. No action is needed.
Install mcemonitor of the
latest version.
Restart mcemonitor
automatically by cron.
Restart mcemonitor
automatically by cron.
Restart mcemonitor
automatically by cron.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Express5800/a2010bExpress5800/a2020bExpress5800/a2040b

Table of Contents