NEC Express5800/A1040b User Manual page 37

Machine check monitoring service
Hide thumbs Also See for Express5800/A1040b:
Table of Contents

Advertisement

No.
Message
62
cannot bind to NETLINK socket
<error cause>
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
63
cannot set FD_CLOEXEC flag on
fd <error cause>
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
64
poll table overflow
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
65
cannot set FD_CLOEXEC flag on
fd
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
66
poll table overflow
mcemonitor exited due to a system
error. mcemonitor will be restarted
by cron.
67
poll error <error cause>
mcemonitor found a continuable
error. mcemonitor will continue to
be run safely.
68
Offlining CPU xx due to corrected
error threshold
69
Not offlining CPU 0 because of
kernel running on CPU 0.
70
Offlining CPU xx succeeded
71
Offlining CPU xx failed
72
Kernel does not support page
offline interface
73
Corrected memory errors on page
xx exceeded threshold
74
Offlining page xx due to corrected
error threshold
75
Not offlining page xx because this
offlining page has already
succeeded.
76
Not offlining page xx because this
offlining page has already failed.
77
Soft offlining of page xx
succeeded.
78
Soft offlining of page xx failed.
79
mcemonitor already running
Meaning
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
An error occurred on
system-related function, and
mcemonitor exited. mcemonitor
is restarted by cron.
An error occurred on
system-related function, but
mcemonitor continue operation.
Offline CPU xx due to corrected
error exceeds threshold.
Cannot offline CPU 0 because its
kernel is running.
Offlining CPU xx succeeded.
Offlineing CPU xx failed because
it was in use.
Kernel does not support
MemoryPage Offline.
Correctable memory error on
page xx exceeded threshold
value.
Memory error on address xx
exceeded threshold value.
Offline memory page.
Do not offline memory page
because memory address xx has
already been offlined.
Do not offline memory page
because memory address xx has
already been offlined.
Memory Page Offline was
executed on address xx in Soft
Mode.
Could not offline the memory
page because the page was in
use.
mcemonitor is already running.
33
Action
Restart mcemonitor
automatically by cron.
Restart mcemonitor
automatically by cron.
Restart mcemonitor
automatically by cron.
Restart mcemonitor
automatically by cron.
Restart mcemonitor
automatically by cron.
mcemonitor continues
running. No action is needed.
Could not offline the memory
page because the page was
in use. Use syslog to confirm
attribute of page.