6.4

Storage memory (optional)

Sizes :
6.5

Computer communication

Data is transferred in a serial form to and from the computer. The serial
standard conforms to a subset of RS-232.
Format :
Signals :
(pin no.)
Handshaking :
6.6

Commands

See separate manual: "Command manual".
28
0k bytes (only on-line usage)
64k bytes
544k bytes
1046k bytes
Every stored measurement value
occupies two bytes.
8 bit ASCII
1 start bit
8 data bits
1 stop bit
19200 baud
Tx
(2)
Rx
(3)
CTS
(5)
DTR
(6)
GND
(7)
Hardware handshaking is employed.
DTR : Signals that the logger is operational
(output)
CTS : Signal allowing the logger to transmit
(input)