2.1
Ranges: Voltage and Current
Each programmable (option) range or preset range has a resolution of at least
+/-1800 divisions.
Translated into measured units this can be illustrated like this:
RANGE
+/-10V
+/-1000mV
+/-100mV
+/-50mV
+/-20mA
Each channel has an internal 51Ω shunt that is used to measure current. It is
connected into the input circuitry by putting the small DIP-switch in position
"current".
8
RESOLUTION
5.5mV
0.55mV
0.055mV
30µV
11µA
INTAB Interface-Teknik AB
ACCURACY
0.12% of FSR
0.12% of FSR
0.12% of FSR
0.12% of FSR
0.12% of FSR