Download Print this page

Advertisement

Quick Links

FOR YOUR SAFETY - This product must be serviced by a contractor who is licensed and qualified in pool equipment by the
jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or local
requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and
maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow
all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in
property damage, personal injury, or death. Improper installation and/or operation will void the warranty.
Improper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or
death.
Connect unit to receptacle protected by a ground fault circuit interrupter (GFCI). Such a GFCI receptacle should be provided by
a qualified installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI should interrupt
power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the
GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility
of an electric shock. Do not use this product. Disconnect the cleaner and have the problem corrected by a qualified service
representative before using.
KEEP OUT OF REACH OF CHILDREN
1. Introduction
This document gives diagnostic testing instructions
for the 9300/9300xi Sport.
The instructions were written with safety as the
priority and must be followed exactly. Not following
the written procedure or taking shortcuts may
increase the risk of personal injury. Read through
the instructions completely before starting the
procedure.
2. Diagnostic Instructions
The customer must provide the following items to
perform the diagnostic testing:
• Control Unit
• Cleaner Head with Floating Cable
Polaris 9300/9300xi Diagnostic Instructions
WARN ING
Figure 1.
Future
Use
Press to
Press to START
STOP the test
9300 or 9300xi test
Polaris Quick Diagnostic Test Box

Advertisement

loading

Summary of Contents for Polaris 9300

  • Page 1 Polaris 9300/9300xi Diagnostic Instructions WARN ING FOR YOUR SAFETY - This product must be serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exists. In the event no such state or local requirement exists, the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly.
  • Page 2 Set the cleaner head on a block of wood or some object that allows the cleaner wheels to be elevated from the surface. Plug the Polaris Quick Diagnostic Test Box into a GFCI protected outlet. Connect the fl oating cable from the cleaner to the test box (see Figure 2).
  • Page 3 Page 3 If the pump and drive motors drive, the control unit Close the cover and turn the cleaner over so that it’s has passed the test successfully. Turn off the power resting on its top. to the control unit. Remove the four (4) screws from the bottom of the NOTE The control unit is programmed to shut down cleaner.
  • Page 4 Using the short test cable, connect the motor block to Once secured, start the diagnostic test (see Figure 11). the Polaris Quick Diagnostic Test Box (see Figure 10). Figure 11. Testing the Motor Block Figure 10. Motor Block Connected to Test Box If the test completes without fl...