Rated conditions
Degree of protection (to EN 60529)
Electromagnetic compatibility
Construction
Weight
Process connections
Electrical connections
Material of the wetted parts
● Measuring cell
● Process connection
Material of the non-wetted parts
● Enclosure
● Rack
● Cable
Explosion protection 7MF1567-....1-....
Intrinsic safety "i" (only with current output)
EC type-examination certificate
Connection to certified intrinsically-safe resistive
circuits with maximum values
Effective internal inductance and capacitance for
versions with connections to EN 175301-803-A
and M12
SITRANS P220
Compact Operating Instructions, 02/2019, A5E03304437-AB
● IP65 with connector to EN 175301-803-A
● IP67 with M12 connector
● IP67 with cable
● IP67 with fast-fit cable gland
● To EN 61326-1
● To EN 61326-2-3
● To NAMUR NE21, only for ATEX devices and
with a max. measurement error of ≤ 1%
Approx. 0.090 kg (0.198 lb)
Dimension drawings (Page 31)
● Connector to EN 175301-803-A Form A with cable inlet M16x1.5
or ½-14NPT or Pg 11
● M12 connector
● 2 or 3-wire (0.5 mm
) cable (∅ ± 5.4 mm)
2
● Fast-fit cable gland
Stainless steel, Mat. No. 1.4016
Stainless steel, Mat. No. 1.4404 (SST 316 L)
Stainless steel, Mat. No. 1.4404 (SST 316 L)
● Plastic
● CuZn, nickel-plated (M12 connector)
PVC spec.
II 1/2 G Ex ia IIC T4 Ga/Gb
II 1/2 D Ex ia IIIC T125 °C Da/Db
SEV 10 ATEX 0146
U
≤ 30 VDC; I
i
L
= 0 nH; C
i
Technical specifications
≤ 100 mA; P
≤ 0.75 W
i
i
= 0 nF